Evidence map›Paper›PMID 38180547›Full record

ArticleEJNMMI research2024

Effects of isoflurane anaesthesia depth and duration on renal function measured with [

Fabian Schmitz-Peiffer, Mathias Lukas, Ajay-Mohan Mohan, Jakob Albrecht, Jörg R Aschenbach, Winfried Brenner, Nicola Beindorff

Open access · goldAbstract read
In one paragraph

Article in EJNMMI research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Fabian Schmitz-PeifferDepartment of Nuclear Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.
Mathias LukasDepartment of Nuclear Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.
Ajay-Mohan MohanDepartment of Nuclear Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.
Jakob AlbrechtDepartment of Nuclear Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.
Jörg R AschenbachInstitute of Veterinary Physiology, School of Veterinary Medicine, Freie Universität Berlin, Berlin, Germany.
Winfried BrennerDepartment of Nuclear Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.
Nicola BeindorffBerlin Experimental Radionuclide Imaging Center (BERIC), Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany. nicola.beindorff@charite.de.ORCID http://orcid.org/0000-0001-9126-3356
Charité - Universitätsmedizin Berlin · DEFreie Universität Berlin · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe influence of anaesthetic depth and the potential influence of different anaesthetic beds and thus different handling procedures were investigated in 86 severe combined immunodeficient (SCID) mice using semi-stationary dynamic single photon emission computed tomography (SPECT) for kidney scintigraphy. Therefore, isoflurane concentrations were adjusted using respiratory rate for low (80-90 breath/min) and deep anaesthesia (40-45 breath/min). At low anaesthesia, we additionally tested the influence of single bed versus 3-mouse bed hotel; the hotel mice were anaesthetized consecutively at ~ 30, 20, and 10 min before tracer injections for positions 1, 2, and 3, respectively. Intravenous [

resultsLow and deep anaesthesia corresponded to median isoflurane concentrations of 1.3% and 1.5%, respectively, with no significant differences in heart rate (p = 0.74). Low anaesthesia resulted in shorter aortic blood clearance half-life (p = 0.091) and increased relative renal tracer influx rate (p = 0.018). A tendency toward earlier Tmax occurred under low anaesthesia (p = 0.063) with no differences in T50 (p = 0.40) and T25 (p = 0.24). Variance increased with deep anaesthesia. Compared to single mouse scans, hotel mice in position 1 showed a delayed Tmax, T50, and T25 (p < 0.05 each). Furthermore, hotel mice in position 1 showed delayed Tmax versus position 3, and delayed T50 and T25 versus position 2 and 3 (p < 0.05 each). No difference occurred between single bed and positions 2 (p = 1.0) and 3 (p = 1.0).

conclusionsDeep anaesthesia and prolonged low anaesthesia should be avoided during renal scintigraphy because they result in prolonged blood clearance half-life, delayed renal influx and/or later Tmax. Vice versa, low anaesthesia with high respiratory rates of 80-90 rpm and short duration (≤ 20 min) should be preferred to obtain representative data with low variance.

Indexed as

[99mTc]Tc-MAG3HotelIsoflurane concentrationRespiratory rateSingle mouse bed

Identifiers

PMID38180547
PMCPMC10769950
OpenAlexW4390631535

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.