Evidence map›Paper›PMID 38179508›Full record

ArticleFrontiers in cardiovascular medicine2023

The feasibility of relaxation-enhanced angiography without contrast and triggering for preprocedural planning of transcatheter aortic valve implantation.

Rui Wang, Xinmin Liu, Jing Yao, U Joseph Schoepf, Joseph Griffith, Jiayang Wang, Jianxiu Lian, Ke Jiang, Guangyuan Song, Lei Xu

Open access · goldAbstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 65% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Rui Wang *Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Xinmin Liu *Interventional Center of Valvular Heart Disease, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Jing YaoInterventional Center of Valvular Heart Disease, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
U Joseph SchoepfDivision of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC, United States.
Joseph GriffithDivision of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC, United States.
Jiayang WangCenter of Coronary Artery Surgery, Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Jianxiu LianPhilips Healthcare, Beijing, China.
Ke JiangPhilips Healthcare, Beijing, China.
Guangyuan Song *Interventional Center of Valvular Heart Disease, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Lei Xu *Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Beijing Anzhen Hospital · CNCapital Medical University · CNMedical University of South Carolina · USPhilips (China) · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Cardiovascular MRI is advantageous in transcatheter aortic valve implantation (TAVI) planning. This study aimed to evaluate the feasibility of comprehensive non-contrast MRI [relaxation-enhanced angiography without contrast and triggering (REACT)] combined with a three-dimensional whole-heart MRI protocol for preprocedural planning of TAVI vs. computed tomography angiography (CTA). Methods: Thirty patients with severe aortic stenosis were prospectively enrolled. The anatomical properties of the aortic root anatomy, including the perimeter and area of the virtual aortic valve annulus and coronary heights, were determined from 3D whole-heart MRI and cardiac CTA (CCTA) images, respectively. The diameters of the aorta (thoracic and abdominal aorta) and iliofemoral arteries were measured from REACT and aortic CTA (ACTA) images, respectively. A paired Results: All 30 patients completed CTA and cardiovascular MRI examinations, with the TAVI procedure being administered in 25 patients. The mean acquisition time of the comprehensive MRI protocol was 18 ± 3.2 min. There were no significant differences between ACTA and REACT data in regard to the diameters of aortic and iliofemoral arteries, including the ascending thoracic aorta (37 ± 4.6 mm vs. 37.7 ± 5.2 mm, Conclusion: REACT combined with 3D whole-heart MRI enables reliable measurements of aortic root anatomy, annular calcification, and aorta and iliofemoral access in patients under evaluation for TAVI.

Indexed as

3D whole-heart MRIcardiac MRICT angiographyMRItranscatheter aortic valve implantation

Identifiers

PMID38179508
PMCPMC10766106
OpenAlexW4389726941

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.