Evidence map›Paper›PMID 38179134›Full record

ArticleFrontiers in bioengineering and biotechnology2023

Computational study of the balloon dilation steps on transcatheter aortic valve replacement.

Jianming Li, Zhuangyuan Meng, Wentao Yan, Wenshuo Wang, Lai Wei, Shengzhang Wang

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Jianming LiDepartment of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China.
Zhuangyuan MengDepartment of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China.
Wentao YanShanghai Inspection and Research Institute for Medical Devices, Shanghai, China.
Wenshuo WangDepartment of Cardiac Surgery, Zhongshan Hospital Affiliated to Fudan University, Shanghai, China.
Lai WeiDepartment of Cardiac Surgery, Zhongshan Hospital Affiliated to Fudan University, Shanghai, China.
Shengzhang WangDepartment of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China.
Fudan University · CNShanghai Special Equipment Supervision and Inspection Institute · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Balloon dilation is a commonly used assistant method in transcatheter aortic valve replacement (TAVR) and plays an important role during valve implantation procedure. The balloon dilation steps need to be fully considered in TAVR numerical simulations. This study aims to establish a TAVR simulation procedure with two different balloon dilation steps to analyze the impact of balloon dilation on the results of TAVR implantation. Two cases of aortic stenosis were constructed based on medical images. An implantation simulation procedure with self-expandable valve was established, and multiple models including different simulation steps such as balloon pre-dilation and balloon post-dilation were constructed to compare the different effects on vascular stress, stent morphology and paravalvular leakage. Results show that balloon pre-dilation of TAVR makes less impact on post-operative outcomes, while post-dilation can effectively improve the implantation morphology of the stent, which is beneficial to the function and durability of the valve. It can effectively improve the adhesion of the stent and reduce the paravalvular leakage volume more than 30% after implantation. However, balloon post-dilation may also lead to about 20% or more increased stress on the aorta and increase the risk of damage. The balloon dilation makes an important impact on the TAVR outcomes. Balloon dilation needs to be fully considered during pre-operative analysis to obtain a better clinical result.

Indexed as

numerical simulationpost-dilationpre-dilationself-expandable valvetranscatheter aortic valve replacement

Identifiers

PMID38179134
PMCPMC10765527
OpenAlexW4390008423

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.