Evidence map›Paper›PMID 38178497›Full record

ArticleOptics express2023

Robust real-time estimation of non-uniform angular velocity and sub-pixel jitter in images captured with resonant scanners.

Gastón A Ayubi, Alfredo Dubra

Open access · goldAbstract read
In one paragraph

Article in Optics express, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.6field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Gastón A Ayubi
Alfredo Dubra

Funding

Stanford Vision Research CoreP30EY026877 · NEI · STANFORD UNIVERSITY · PI Jeffrey L Goldberg · 2017 to 2026
$8.0M
Increasing the isoplanatic patch in adaptive optics ophthalmoscopyR01EY032147 · NEI · STANFORD UNIVERSITY · PI DUBRA, ALFREDO · 2021 to 2025
$2.4M
Improving rigor and reproducibility in adaptive optics ophthalmoscopyR01EY031360 · NEI · STANFORD UNIVERSITY · PI DUBRA, ALFREDO · 2020 to 2023
$2.3M
Structural and functional tests of ganglion cell damage in glaucomaR01EY030361 · NEI · STANFORD UNIVERSITY · PI GOLDBERG, JEFFREY L, NORCIA, ANTHONY M · 2019 to 2022
$2.1M
Low Latency Eye-Motion CompensationR01EY032669 · NEI · STANFORD UNIVERSITY · PI DUBRA, ALFREDO · 2021 to 2024
$1.8M
NEI NIH HHS P30 EY026877NEI NIH HHS R01 EY030361NEI NIH HHS R01 EY031360NEI NIH HHS R01 EY032147NEI NIH HHS R01 EY032669
6 · The paper itself

Abstract

Images captured with resonant scanners are affected by angular velocity fluctuations that result in image distortion and by poor synchronization between scanning and light detection that creates jitter between image rows. We previously demonstrated that both problems can be mitigated in post-processing by recording the scanner orientation in synchrony with the image capture, followed by data resampling [Opt. Express30, 112 (2022)10.1364/OE.446162]. Here we introduce more robust algorithms for estimation of both angular velocity fluctuation and jitter in the presence of random and deterministic noise. We also show linearization of the scanner oscillation model to reduce calculation times by two orders of magnitude, reaching 65,000 jitter estimations per second when using 2,800 samples per image row, and 500,000 when using only 500 samples, easily supporting real-time generation of jitter-corrected images.

Identifiers

PMID38178497
PMCPMC13372339
OpenAlexW4389394727

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked