ArticleJournal of orthopaedic surgery and research2024
The positional consistency between guidewire and cannulated or solid screw in robot-assisted spinal internal fixation surgery.
Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Mechanical validation of 3D-printed orthopaedic surrogate models for screw insertion training.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundThis study aimed to investigate the positional consistency between the guidewire and the screw in spinal internal fixation surgery.
methodsThis study involved 64 patients who underwent robot-assisted thoracic or lumbar pedicle screw fixation surgery. Guidewires were inserted with the assistance of the Tirobot. Either cannulated screws or solid screws were inserted. Guidewire and screw accuracy was measured using CT images based on the Gertzbein and Robbins scale. The positional consistency between guidewire and screw was evaluated based on the fused CT images, which could graphically and quantitatively demonstrate the consistency. The consistency was evaluated based on a grading system that considered the maximum distance and angulation between the centerline of the guidewire and the screw in the region of the pedicle.
resultsA total of 322 screws were placed including 206 cannulated ones and 116 solid ones. Based on the Gertzbein and Robbins scale, 97.5% of the guidewires were grade A, and 94.1% of the screws were grade A. Based on our guidewire-screw consistency scale, 85% in cannulated group, and 69.8% in solid group, were grade A. Both solid and cannulated screws may alter trajectory compared to the guidewires. The positional accuracy and guidewire-screw consistency in the solid screw group is significantly worse than that in the cannulated screw group. The cortical bone of the pedicle has a positive guide effect on either solid or cannulated screws.
conclusionThe pedicle screws may alter trajectory despite the guidance of the guidewires. Solid screws show worse positional accuracy and guidewire-screw consistency compared with cannulated screws. Trial registration The study was retrospectively registered and approved by our center's institutional review board.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.