Evidence map›Paper›PMID 38178197›Full record

ArticleJournal of orthopaedic surgery and research2024

The positional consistency between guidewire and cannulated or solid screw in robot-assisted spinal internal fixation surgery.

Jingwei Zhao, Yunxian Zhang, Mingxing Fan, Xiaoguang Han, Bo Liu, Da He, Wei Tian

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Mechanical validation of 3D-printed orthopaedic surrogate models for screw insertion training.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Jingwei Zhao *Department of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China. kivist@163.com.
Yunxian Zhang *School of Biomedical Engineering, Capital Medical University, Beijing, China.
Mingxing FanDepartment of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
Xiaoguang HanDepartment of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
Bo LiuDepartment of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
Da HeDepartment of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
Wei TianDepartment of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China. tianwjst@163.com.
Capital Medical University · CNChinese Academy of Medical Sciences & Peking Union Medical College · CN

Funding

Beijing Natural Science Foundation L202005Capital's Funds for Health Improvement and Research 2020-2-2072Nova Program of Beijing Jishuitan Hospital XKXX202210the CAMS Innovation Fund for Medical Sciences (CIFMS) 2021-I2M-5-007
6 · The paper itself

Abstract

backgroundThis study aimed to investigate the positional consistency between the guidewire and the screw in spinal internal fixation surgery.

methodsThis study involved 64 patients who underwent robot-assisted thoracic or lumbar pedicle screw fixation surgery. Guidewires were inserted with the assistance of the Tirobot. Either cannulated screws or solid screws were inserted. Guidewire and screw accuracy was measured using CT images based on the Gertzbein and Robbins scale. The positional consistency between guidewire and screw was evaluated based on the fused CT images, which could graphically and quantitatively demonstrate the consistency. The consistency was evaluated based on a grading system that considered the maximum distance and angulation between the centerline of the guidewire and the screw in the region of the pedicle.

resultsA total of 322 screws were placed including 206 cannulated ones and 116 solid ones. Based on the Gertzbein and Robbins scale, 97.5% of the guidewires were grade A, and 94.1% of the screws were grade A. Based on our guidewire-screw consistency scale, 85% in cannulated group, and 69.8% in solid group, were grade A. Both solid and cannulated screws may alter trajectory compared to the guidewires. The positional accuracy and guidewire-screw consistency in the solid screw group is significantly worse than that in the cannulated screw group. The cortical bone of the pedicle has a positive guide effect on either solid or cannulated screws.

conclusionThe pedicle screws may alter trajectory despite the guidance of the guidewires. Solid screws show worse positional accuracy and guidewire-screw consistency compared with cannulated screws. Trial registration The study was retrospectively registered and approved by our center's institutional review board.

Indexed as

Pedicle ScrewsRoboticsRobotic Surgical ProceduresSurgery, Computer-AssistedHumansSpineCone-beam CTGuidewireImage fusionIntra-operative CTPercutaneousPositional consistencyPost-operative CTRobot-assistedScrewSpinal surgery

Identifiers

PMID38178197
PMCPMC10768200
OpenAlexW4390598651

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked