Structural and torque changes in implant components of different diameters subjected to mechanical fatigue.

Renan Brandenburg Dos Santos, Ulysses Lenz, Jason Alan Griggs, Carlos Estrela, Mike Dos Reis Bueno, Olavo Cesar Lyra Porto, Alvaro Della Bona

Abstract read
In one paragraph

Article in Dental materials : official publication of the Academy of Dental Materials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Renan Brandenburg Dos SantosPostgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil.
Ulysses LenzPostgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil.
Jason Alan GriggsDepartment of Biomedical Materials Science, University of Mississippi Medical Center, MS, USA.
Carlos EstrelaSchool of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil.
Mike Dos Reis BuenoSchool of Dentistry, São Leopoldo Mandic, Campinas, SP, Brazil.
Olavo Cesar Lyra PortoSchool of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil.
Alvaro Della BonaPostgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil. Electronic address: dbona@upf.br.

Funding

Design Optimization of Reduced-Diameter Implants in Simulated and Cadaver BoneR01DE026144 · NIDCR · UNIVERSITY OF MISSISSIPPI MED CTR · PI GRIGGS, JASON A · 2019 to 2023
$1.8M
NIDCR NIH HHS R01 DE026144
6 · The paper itself

Abstract

objectivesTo evaluate torque maintenance and structural damage in implant components of different diameters subjected to a fatigue challenge.

methodsThirty 10-mm-long, morse taper connection, titanium dental implants and their corresponding one-piece abutments were divided into three groups (n = 10) according to implant diameter: 4.3 mm (I4.3), 3.5 mm (I3.5), and 2.9 mm (I2.9). The implants were placed into a load-bearing fixture simulating bone tissue (modified G10), and the abutments were screwed into the implants to a final torque of 20 Ncm for the I4.3 and I3.5 and 15 Ncm for I2.9. The torque was secured by a digital torque meter. Cone-beam computed tomography (CBCT) scans were acquired and post-processed (e-Vol DX software) for all implant/abutment sets before and after subjecting them to fatigue in 37 °C distilled water (2 million cycles, constant load and frequency). The removal torque was measured using the same digital torque meter to calculate the difference in torque before and after fatigue.

resultsI2.9 showed substantial structural deformation compared with the other implant diameters (I3.5 and I4.3). However, the experimental groups did not show statistical differences for abutment loosening. SIGNIFICANCE: Implants smaller than 3.5 mm in diameter have a higher probability of structural deformation than standard-diameter implants. The association between tomographic scans and e-Vol DX software showed satisfactory consistency with the direct assessment using the digital torque meter, offering an additional tool to evaluate implant component loosening and structural deformations.

Indexed as

Dental ImplantsDental AbutmentsDental Implant-Abutment DesignDental Stress AnalysisTorqueDental ImplantsCone-beam computed tomographyE-Vol DX softwareFatigueNarrow-diameter implantsSmall dental implants

Identifiers

PMID38176998
PMCPMC10942759

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.