Evidence map›Paper›PMID 38175269›Full record

ArticleBiomedical microdevices2024

The effect of magnetic bead size on the isolation efficiency of lung cancer cells in a serpentine microchannel with added cavities.

Tzu-Cheng Su, Hien Vu-Dinh, Shu-Hui Lin, Loc Do Quang, Trinh Chu Duc, Chun-Ping Jen

Abstract read
PubMed Publisher
In one paragraph

Article in Biomedical microdevices, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Tzu-Cheng SuDepartment of Surgical Pathology, Changhua Christian Hospital, Changhua, 500, Taiwan, R.O.C.
Hien Vu-DinhDepartment of Mechanical Engineering and Advanced Institute of Manufacturing for High-Tech Innovations, National Chung Cheng University, Chia-Yi, 62102, Taiwan, R.O.C.
Shu-Hui LinDepartment of Surgical Pathology, Changhua Christian Hospital, Changhua, 500, Taiwan, R.O.C.
Loc Do QuangFaculty of Physics, University of Science, Vietnam National University, Hanoi, 100000, Vietnam.
Trinh Chu DucFaculty of Electronics and Telecommunication, University of Engineering and Technology, Vietnam National University, Hanoi, 100000, Vietnam.
Chun-Ping JenDepartment of Mechanical Engineering and Advanced Institute of Manufacturing for High-Tech Innovations, National Chung Cheng University, Chia-Yi, 62102, Taiwan, R.O.C.. chunpingjen@alum.ccu.edu.tw.
National Chung Cheng University · TWVietnam National University, Hanoi · VNCentral Taiwan University of Science and Technology · TWChanghua Christian Hospital · TW

Funding

Ministry of Science and Technology, Taiwan MOST 111-2923-E-194-001-MY3
6 · The paper itself

Abstract

An investigation was conducted to examine the effect of magnetic bead (MB) size on the effectiveness of isolating lung cancer cells using the immunomagnetic separation (IMS) method in a serpentine microchannel with added cavities (SMAC) structure. Carboxylated magnetic beads were specifically conjugated to target cells through a modification procedure using aptamer materials. Cells immobilized with different sizes (in micrometers) of MBs were captured and isolated in the proposed device for comparison and analysis. The study yields significance regarding the clarification of device working principles by using a computational model. Furthermore, an accurate evaluation of the MB size impact on capture efficiency was achieved, including the issue of MB-cell accumulation at the inlet-channel interface, despite it being overlooked in many previous studies. As a result, our findings demonstrated an increasing trend in binding efficiency as the MB size decreased, evidenced by coverages of 50.5%, 60.1%, and 73.4% for sizes of 1.36 μm, 3.00 μm, and 4.50 μm, respectively. Additionally, the overall capture efficiency (without considering the inlet accumulation) was also higher for smaller MBs. However, when accounting for the actual number of cells entering the channel (i.e., the effective capture), larger MBs showed higher capture efficiency. The highest effective capture achieved was 88.4% for the size of 4.50 μm. This research provides an extensive insight into the impact of MB size on the performance of IMS-based devices and holds promise for the efficient separation of circulating cancer cells (CTCs) in practical applications.

Indexed as

Lung NeoplasmsNeoplastic Cells, CirculatingCarboxylic AcidsHumansImmunomagnetic SeparationMagnetic PhenomenaCarboxylic AcidsAptamersCirculating tumor cellsImmunomagnetic separationMicrofluidics

Identifiers

PMID38175269
OpenAlexW4390586991

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.