Evidence map›Paper›PMID 38173871›Full record

ArticleFrontiers in bioengineering and biotechnology2023

Patricia Cintora-López, Patricia Arrieta-Blanco, Andrea Martin-Vacas, Marta Macarena Paz-Cortés, Javier Gil, Juan Manuel Aragoneses

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Patricia Cintora-LópezFaculty of Dentistry, Alfonso X El Sabio University, Villanueva de la Cañada, Spain.
Patricia Arrieta-BlancoFaculty of Dentistry, Alfonso X El Sabio University, Villanueva de la Cañada, Spain.
Andrea Martin-VacasFaculty of Dentistry, Alfonso X El Sabio University, Villanueva de la Cañada, Spain.
Marta Macarena Paz-CortésFaculty of Dentistry, Alfonso X El Sabio University, Villanueva de la Cañada, Spain.
Javier GilFaculty of Medicine and Health Sciences, Bionegineering Institute of Technology, International University of Catalunya, Barcelona, Spain.
Juan Manuel AragonesesFaculty of Dentistry, Alfonso X El Sabio University, Villanueva de la Cañada, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The mechanical properties of polyurethane dental aligners have been studied in an oral environment at 37°C and subjected to thermal cycling between 5°C and 55°C for long periods of time at different mechanical stresses. The aim is to determine the efficacy of the orthodontic aligner at different stress levels, the effect of thermal cycling with therapy time on tooth position correction. Sixty aligners with the same design were studied applying tensions of 0, 3 and 30 N and determining the deformation at different times from 1 to 760 h. Half of these aligners were subjected to stresses submerged in artificial saliva at 37°C and the other half were subjected to thermal cycles between 2°C and 55°C in salivary medium. Deformation was determined using a high-resolution stereo magnifier and ImageJ image analysis software. Water adsorption by the polyurethane was determined at the different test times. The results showed that in the unloaded aligners there is no appreciable deformation, but with thermal cycling there is a light shrinkage of the aligner due to the semi-crystallization process (ordering of polymeric chains) of the polyurethane. When applying loads of 3 and 30 N, creep curves with constant deformation transition zones can be seen. The transition zones decrease as the applied mechanical load increases. In addition, the significant effect of thermal cycling on the reduction of the transition zone of the aligners has been demonstrated. The transition zones are optimal for dental correction as constant stresses are exerted for tooth movement. The effect of thermal cycling shortens the constant deformation zone and reduces tooth alignment time. It was observed that the absorption of water in the aligner is constant after 1 h of immersion and does not exceed 0.4% by weight of absorbed water.

Indexed as

clear aligner appliancescreepmechanical propertiesorthodontic appliances, removablepolymers

Identifiers

PMID38173871
PMCPMC10761475

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.