Evidence map›Paper›PMID 38172486›Full record

ArticleEuropean radiology experimental2024

Cardiac-induced motion of the pancreas and its effect on image quality of ultrahigh-resolution CT.

Thomas Wesley Holmes, Zhou Yu, Richard Thompson, John N Oshinski, Amir Pourmorteza

Open access · goldAbstract read
In one paragraph

Article in European radiology experimental, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Thomas Wesley HolmesDepartment of Radiology and Imaging Sciences, Emory University, 1364 Clifton Road NE, Atlanta, GA, 30322, USA.
Zhou YuCanon Medical Research USA, Inc, 706 N. Deerpath Drive, Vernon Hills, IL, 60061, USA.
Richard ThompsonCanon Medical Research USA, Inc, 706 N. Deerpath Drive, Vernon Hills, IL, 60061, USA.
John N OshinskiDepartment of Radiology and Imaging Sciences, Emory University, 1364 Clifton Road NE, Atlanta, GA, 30322, USA.
Amir PourmortezaDepartment of Radiology and Imaging Sciences, Emory University, 1364 Clifton Road NE, Atlanta, GA, 30322, USA. Amir.pourmorteza@gmail.com.ORCID 0000-0001-7149-5424
Canon (United States) · USGeorgia Institute of Technology · USEmory University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recent advancements in diagnostic CT detector technology have made it possible to resolve anatomical features smaller than 20 LP/cm, referred to as ultra-high-resolution (UHR) CT. Subtle biological motions that did not affect standard-resolution (SR) CT may not be neglected in UHR. This study aimed to quantify the cardiac-induced motion of the pancreas and simulate its impact on the image quality of UHR-CT. We measured the displacement of the head of the pancreas in three healthy volunteers using Displacement Encoding with Stimulated Echoes (DENSE) MRI. The results were used to simulate SR- and UHR-CT acquisitions affected by pancreatic motion.We found pancreatic displacement in the 0.24-1.59 mm range during one cardiac cycle across the subjects. The greatest displacement was observed in the anterior-posterior direction. The time to peak displacement varied across subjects. Both SR and UHR images showed reduced image quality, as measured by radial modulation transfer function, due to cardiac-induced motion, but the motion artifacts caused more severe degradation in UHR acquisitions. Our investigation of cardiac-induced pancreatic displacement reveals its potential to degrade both standard and UHR-CT scans. To fully utilize the improvement in spatial resolution offered by UHR-CT, the effects of cardiac-induced motion in the abdomen need to be understood and corrected.Relevance statement Advancements in CT detector technology have enhanced CT scanner spatial resolution to approximately 100 µm. Consequently, previously ignored biological motions such as the cardiac-induced motion of the pancreas now demand attention to fully utilize this improved resolution.

Indexed as

Abdominal CavityTomography, X-Ray ComputedHumansMotionPancreasTomography Scanners, X-Ray ComputedAbdomenArtifactsHealthy volunteersMagnetic resonance imagingTomography (x-ray computed)

Identifiers

PMID38172486
PMCPMC10764702
OpenAlexW4390570790

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.