Observational studyJournal of anesthesia2024
Changes in the corrected carotid flow time can predict spinal anesthesia-induced hypotension in patients undergoing cesarean delivery: an observational study.
Observational study in Journal of anesthesia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 10 citations in OpenAlex.
- Fluid responsiveness-guided individualized strategy for preventing hypotension after spinal anesthesia in cesarean delivery: a randomized trial of prehydration versus norepinephrine preinfusion.BMC anesthesiology · 2026Trial
- Carotid flow time: a new surrogate for fluid responsiveness?Journal of anesthesia · 2026Article
- Carotid corrected flow time as a sensitive indicator for early diagnosis and dynamic monitoring of hemorrhagic shock: A translational study from porcine model to clinical practice.Chinese journal of traumatology = Zhonghua chuang shang za zhi · 2026Article
- Position-Induced Change in Carotid Corrected Flow Time Predicts Spinal Hypotension in Cesarean Delivery.International journal of women's health · 2026Article
- Reply to the letter.Journal of anesthesia · 2024Article
- Letter to the article by Juri et al.Journal of anesthesia · 2024Article
- Reply to the letter.Journal of anesthesia · 2024Article
- Advances in the application of ultrasonographic parameters for fluid management in obstetric anesthesia.American journal of translational research · 2024Review
- The impact of pre-rehydration guided by carotid corrected flow time on hypotension prevention following general anesthesia induction in patients undergoing gastrointestinal surgery: a prospective randomized controlled trial.Frontiers in medicine · 2024Article
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeSpinal anesthesia is a standard technique for cesarean delivery; however, it possesses a risk of hypotension. We hypothesised that the changes in the corrected flow time induced by the Trendelenburg position could predict the incidence of hypotension after spinal anesthesia for cesarean delivery.
methodsPatients undergoing elective cesarean delivery under spinal anesthesia were enrolled. Before anesthesia induction, corrected flow time was measured in the supine and Trendelenburg positions (FTc-1 and FTc-2, respectively). Additionally, a percent change in corrected flow time induced by the Trendelenburg position was defined as ΔFTc. The primary endpoint was to investigate the ability of ΔFTc to predict the incidence of spinal anesthesia-induced hypotension until delivery. The receiver operating characteristics curves to assess the ability of FTc-1, FTc-2, and ΔFTc to predict the incidence of hypotension were generated.
resultsFinally, 40 patients were included, and of those, 26 (65%) developed spinal anesthesia-induced hypotension. The areas under the curve for FTc-1, FTc-2, and ΔFTc were 0.591 (95% CI: 0.424 to 0.743) (P = 0.380), 0.742 (95% CI: 0.579 to 0.867) (P = 0.004), and 0.882 (95% CI: 0.740 to 0.962) (P < 0.001) respectively, indicating ΔFTc as the best predictor among these three parameters. The best threshold for ΔFTc was 6.4% (sensitivity: 80.8% (95% CI: 53.8 to 96.2), specificity: 85.7% (95% CI: 42.9 to 100.0)).
conclusionsThis study demonstrated that changes in the corrected carotid flow time induced by the Trendelenburg position could serve as a good predictor of spinal anesthesia-induced hypotension for cesarean delivery.