Evidence map›Paper›PMID 38171307›Full record

ArticleNeurospine2023

Biomechanical Study of 3 Osteoconductive Materials Applied in Pedicle Augmentation and Revision for Osteoporotic Vertebrae: Allograft Bone Particles, Calcium Phosphate Cement, Demineralized Bone Matrix.

Chongyu Jia, Renjie Zhang, Jiaqi Wang, Bo Zhang, Huaqing Zhang, Liang Kang, Luping Zhou, Cailiang Shen

Open access · diamondAbstract read
In one paragraph

Article in Neurospine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Personalized Approaches to Spine Surgery.International journal of spine surgery · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Chongyu JiaDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China.
Renjie ZhangDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China.
Jiaqi WangDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China.
Bo ZhangDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China.
Huaqing ZhangDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China.
Liang KangDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China.
Luping ZhouDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China.
Cailiang ShenDepartment of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China.
Anhui Medical University · CN

Funding

First Affiliated Hospital of Anhui Medical University 2020kj06National Key Research and Development Plan Project of Anhui Province 2022YFC2407504
6 · The paper itself

Abstract

objectiveThis study assessed biomechanical properties of pedicle screws enhanced or revised with 3 materials. We aimed to compare the efficacy of these materials in pedicle augmentation and revision.

methodsOne hundred twenty human cadaveric vertebrae were utilized for in vitro testing. Vertebrae bone density was evaluated. Allograft bone particles (ABP), calcium phosphate cement (CPC), and demineralized bone matrix (DBM) were used to augment or revise pedicle screw. Post the implantation of pedicle screws, parameters such as insertional torque, pullout strength, cycles to failure and failure load were measured using specialized instruments.

resultsABP, CPC, and DBM significantly enhanced biomechanical properties of the screws. CPC augmentation showed superior properties compared to ABP or DBM. ABP-augmented screws had higher cycles to failure and failure loads than DBM-augmented screws, with no difference in pullout strength. CPC-revised screws exhibited similar strength to the original screws, while ABP-revised screws showed comparable cycles to failure and failure loads but lower pullout strength. DBM-revised screws did not match the original screws' strength.

conclusionABP, CPC, and DBM effectively improve pedicle screw stability for pedicle augmentation. CPC demonstrated the highest efficacy, followed by ABP, while DBM was less effective. For pedicle revision, CPC is recommended as the primary choice, with ABP as an alternative. However, using DBM for pedicle revision is not recommended.

Indexed as

Biocompatible materialsBiomechanicsBone cementsBone transplantationOsteoporosisSpine

Identifiers

PMID38171307
PMCPMC10762407
OpenAlexW4390295951

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.