ArticlePulmonary therapy2024
Successful Use of Easyhaler
Article in Pulmonary therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Inspiratory Flow Parameters With Placebo Dry Powder Inhalers, Easyhaler and Diskus; an Open, Randomised, Multicentre Study in Patients With Asthma or COPD
Inspiratory Flow Parameters With Placebo Tiotropium Easyhaler® and Placebo Spiriva® Capsule Via HandiHaler® in Patients With COPD and in Healthy Volunteers. Substudy: Easyhaler® and HandiHaler® Usability Study in Patients With COPD
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 6 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThere is increasing pressure to use environmentally friendly dry powder inhalers (DPI) instead of pressurized metered-dose inhalers (pMDI). However, correct inhalation technique is needed for effective inhaler therapy, and there is persistent concern whether patients with chronic obstructive pulmonary disease (COPD) can generate sufficient inspiratory effort to use DPIs successfully. The aims of this study were to find clinical predictors for peak inspiratory flow rate (PIF) and to assess whether patients with COPD had difficulties in generating sufficient PIF with a high resistance DPI.
methodsPooled data of 246 patients with COPD from previous clinical trials was analyzed to find possible predictors of PIF via the DPI Easyhaler (PIFEH) and to assess the proportion of patients able to achieve an inhalation flow rate of 30 l/min, which is needed to use the Easyhaler successfully.
resultsThe mean PIF was 56.9 l/min and 99% (243/246) of the study patients achieved a PIF ≥ 30 l/min. A low PIF was associated with female gender and lower forced expiratory volume in 1 s (FEV1), but the association was weak and a statistical model including both only accounted for 18% of the variation seen in PIFEH.
conclusionsBased on our results, impaired expiratory lung function or patient characteristics do not predict patients' ability to use DPIs in COPD; 99% of the patients generated sufficient PIFEH for successful dose delivery. Considering the targets for sustainability in health care, this should be addressed as DPIs are a potential option for most patients when choosing the right inhaler for the patient.
trial registrationTwo of three included trials were registered under numbers NCT04147572 and NCT01424137. Third trial preceded registration platforms and therefore, was not registered.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.