Evidence map›Paper›PMID 38169937›Full record

ArticleJournal of biomedical optics2024

Scaling down the dimensions of a Fabry-Perot polymer film acoustic sensor for photoacoustic endoscopy.

Tong Li, Tse-Shao Chang, Ahmad Shirazi, Xiaoli Wu, Wei-Kuan Lin, Ruoliu Zhang, Jay L Guo, Kenn R Oldham, Thomas D Wang

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Tong LiUniversity of Michigan, Department of Mechanical Engineering, Ann Arbor, Michigan, United States.ORCID 0009-0001-9049-4301
Tse-Shao ChangUniversity of Michigan, Department of Mechanical Engineering, Ann Arbor, Michigan, United States.ORCID 0000-0003-1787-8744
Ahmad ShiraziUniversity of Michigan, Division of Integrative Systems and Design, Ann Arbor, Michigan, United States.
Xiaoli WuUniversity of Michigan, Department of Internal Medicine, Division of Gastroenterology, Ann Arbor, Michigan, United States.
Wei-Kuan LinUniversity of Michigan, Department of Electrical and Computer Engineering, Ann Arbor, Michigan, United States.ORCID 0000-0002-0935-3916
Ruoliu ZhangUniversity of Michigan, Department of Biomedical Engineering, Ann Arbor, Michigan, United States.
Jay L GuoUniversity of Michigan, Department of Mechanical Engineering, Ann Arbor, Michigan, United States.
Kenn R OldhamUniversity of Michigan, Department of Mechanical Engineering, Ann Arbor, Michigan, United States.ORCID 0000-0002-5962-3056
Thomas D WangUniversity of Michigan, Department of Mechanical Engineering, Ann Arbor, Michigan, United States.ORCID 0000-0001-9182-9620

Funding

Validation & Pathology CoreU54CA163059 · NCI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI RUBENSTEIN, JOEL H, WANG, THOMAS D · 2011 to 2022
$12.1M
Microsystems imaging system for epithelial-derived cancer heterogeneityU01EB028235 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI OLDHAM, KENN R, WANG, THOMAS D · 2019 to 2023
$2.9M
Early detection of colorectal cancer in the traditional and serrated pathwaysR01CA249851 · NCI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI WANG, THOMAS D · 2020 to 2024
$1.7M
NCI NIH HHS R01 CA249851NCI NIH HHS U54 CA163059NIBIB NIH HHS U01 EB028235
6 · The paper itself

Abstract

Significance: A Fabry-Perot (FP) polymer film sensor can be used to detect acoustic waves in a photoacoustic endoscope (PAE) if the dimensions can be adequately scaled down in size. Current FP sensors have limitations in size, sensitivity, and array configurability. Aim: We aim to characterize and demonstrate the imaging performance of a miniature FP sensor to evaluate the effects of reduced size and finite dimensions. Approach: A transfer matrix model was developed to characterize the frequency response of a multilayer miniature FP sensor. An analytical model was derived to describe the effects of a substrate with finite thickness. Finite-element analysis was performed to characterize the temporal response of a sensor with finite dimensions. Miniature Results: The finite thickness substrate of the FP sensor resulted in echoes in the time domain signal that could be removed by back filtering. The substrate acted as a filter in the frequency domain. The finite lateral sensor dimensions produced side waves that could be eliminated by surface averaging using an interrogation beam with adequate diameter. The fabricated FP sensor produced a noise-equivalent pressure = 0.76 kPa, bandwidth of 16.6 MHz, a spectral full-width at-half-maximum = 0.2886 nm, and quality factor Conclusions: A miniature wafer-based FP sensor design has been demonstrated with scaled down form factor for future use in PAE.

Indexed as

AcousticsPolymersAnimalsEndoscopy, GastrointestinalMicePhantoms, ImagingSpectrum AnalysisPolymersfinite-element analysisimaginginterferometerphotoacousticsensortransfer matrix

Identifiers

PMID38169937
PMCPMC10760494

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.