Evidence map›Paper›PMID 38167877›Full record

ArticleScientific reports2024

A bench study on the prevention of lung-to-lung aspiration with double-lumen endobronchial tubes and bronchial blockers.

Hyerim Kim, Taikyung Seol, Sung-Hee Han, Honghyeon Kim, Jin-Young Hwang

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07014345 (Double-Lumen Tube Intubation in the Lateral Position Versus the Supine Position on First-Attempt Success Rate Among Patients Undergoing Thoracic Surgery), which is not on this map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
0.4field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07014345 nawithdrawnnot on this map

Double-Lumen Tube Intubation in the Lateral Position Versus the Supine Position on First-Attempt Success Rate Among Patients Undergoing Thoracic Surgery: A Prospective, Randomized, Controlled, Multi-center Trial

TypeinterventionalSponsorxiangming fangRan2022 to 2023Enrolled0ConditionsDouble Lumen Tube IntubationArmsDLT placement performed in lateral position
3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 1 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Hyerim Kim *Department of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, College of Medicine, Seoul National University, Boramaero 5-Gil, Dongjakgu, Seoul, 07061, Republic of Korea.
Taikyung Seol *Department of Anesthesiology and Pain Medicine, Sheikh Khalifa Specialty Hospital, RAK, United Arab Emirates.
Sung-Hee HanDepartment of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, College of Medicine, Seoul National University, Seoul, Republic of Korea.
Honghyeon KimDepartment of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Jin-Young HwangDepartment of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, College of Medicine, Seoul National University, Boramaero 5-Gil, Dongjakgu, Seoul, 07061, Republic of Korea. mistyblue15@naver.com.
Seoul National University · KRSeoul National University Bundang Hospital · KRShaikh Khalifa Medical City · AE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Effective lung isolation prevents lung-to-lung aspiration during thoracotomy for the management of hemoptysis. Double-lumen endobronchial tubes (DLT) and bronchial blockers are commonly used for lung separation during thoracic surgery. In this study, the fluid-sealing characteristics of the endobronchial cuffs of three different commercially available DLTs (Broncho-Cath with a polyvinylchloride cuff, Broncho-Cath with a polyurethane cuff, and Human Broncho with a silicone cuff) and two different bronchial blockers (Arndt and Coopdech bronchial blockers) were evaluated using a benchtop model. The lateral decubitus position for the surgical management of bleeding from the right lung was simulated. The artificial tracheobronchial tree was placed horizontally, with the left bronchus in the dependent position and the right bronchus in the non-dependent position. In the DLT experiments, the tracheobronchial tree was intubated with left-sided DLTs, and the endobronchial cuff was inflated to maintain the intracuff pressure at 25 cmH

Indexed as

Intubation, IntratrachealThoracic Surgical ProceduresBronchiHumansLungTrachea

Identifiers

PMID38167877
PMCPMC10762100
OpenAlexW4390509716

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.