Evidence map›Paper›PMID 38167750›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Failure after intramedullary nailing for geriatric trochanteric fracture: does quality of fracture reduction on the AP and lateral planes show the same results?

Young-Ho Cho, Sangwoo Kim, Jaewook Koo, Seong-Eun Byun

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.3field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
  3. Factors influencing mechanical failure following intramedullary nailing of proximal femur fractures: a retrospective cohort study.Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2026
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Young-Ho ChoDepartment of Orthopaedic Surgery, Daegu Fatima Hospital, Daegu, Republic of Korea.ORCID http://orcid.org/0000-0002-1527-7761
Sangwoo KimDepartment of Orthopaedic Surgery, Daegu Fatima Hospital, Daegu, Republic of Korea.ORCID http://orcid.org/0000-0003-1708-4901
Jaewook KooDepartment of Orthopaedic Surgery, Daegu Fatima Hospital, Daegu, Republic of Korea.ORCID http://orcid.org/0000-0002-2280-4670
Seong-Eun ByunDepartment of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University, 59 Yatap-Ro, Bundang-Gu, Seongnam-Si, Gyeonggi-Do, 13496, Republic of Korea. sonofos@daum.net.ORCID http://orcid.org/0000-0002-2182-9614
Daegu Fatima Hospital · KRCHA University Bundang Medical Center · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to investigate the failure of trochanteric fracture fixation according to the quality of fracture reduction on the anteroposterior (AP) and lateral views.

methodsData from 340 female and 152 male patients ≥ 60 years of age who underwent intramedullary nailing for a trochanteric fracture between 2016 and 2020 were analysed retrospectively. The quality of fracture reduction was classified as type A, type E, and type I on the AP view and type N, type A, and type P on the lateral view according to the relative position of the proximal and distal fragments. The failure rate was evaluated and compared according to the quality of fracture reduction. The risk factors of the fixation failure were investigated by comparison of variables between patients with and without failure and by regression analysis.

resultsPatients with poor reduction, type I and type P had higher failure rates. However, a statistically significant difference was found only for patients with poor reduction (type P) on the lateral view (p < 0.001). Patients with failure showed significantly higher rates of poor reduction on the lateral view and AO/OTA type A3 fractures. The regression analysis also showed that poor reduction on the lateral view (odds ratio [OR] 12.70; 95% confidence interval [CI] 4.0-40.6; p < 0.001) and AO/OTA type A3 fractures (OR 5.40; 95% CI 1.24-23.49, p = 0.025) were risk factors for failure.

conclusionPoor reduction such as type P reduction was associated with failure after intramedullary nailing for trochanteric fractures. Surgeons should check the quality of fracture reduction carefully with the proper fluoroscopic view to prevent failure in geriatric patients with trochanteric fractures.

Indexed as

Fracture Fixation, IntramedullaryHip FracturesAgedBone NailsFemaleHumansMaleRetrospective StudiesRisk FactorsTreatment OutcomeCut-outFailureFemurIntramedullary nailingReduction qualityTrochanteric fracture

Identifiers

PMID38167750
OpenAlexW4390496606

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.