Evidence map›Paper›PMID 38156737›Full record

ArticleMicroscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada2024

Color Standardization and Stain Intensity Calibration for Whole Slide Image-Based Immunohistochemistry Assessment.

Chie Ohnishi, Takashi Ohnishi, Kareem Ibrahim, Peter Ntiamoah, Dara Ross, Masahiro Yamaguchi, Yukako Yagi

Abstract read
In one paragraph

Article in Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Chie OhnishiDepartment of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1133 York Avenue, New York, NY 10065, USA.ORCID 0000-0002-7327-9116
Takashi OhnishiDepartment of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1133 York Avenue, New York, NY 10065, USA.ORCID 0000-0002-6152-4487
Kareem IbrahimDepartment of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1133 York Avenue, New York, NY 10065, USA.
Peter NtiamoahDepartment of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1133 York Avenue, New York, NY 10065, USA.
Dara RossDepartment of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1133 York Avenue, New York, NY 10065, USA.
Masahiro YamaguchiSchool of Engineering, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama, Kanagawa 226-8503, Japan.
Yukako YagiDepartment of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, 1133 York Avenue, New York, NY 10065, USA.

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748NCI NIH HHS P30CA008748NIH HHS
6 · The paper itself

Abstract

Automated quantification of human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC) using whole slide imaging (WSI) is expected to eliminate subjectivity in visual assessment. However, the color intensity in WSI varies depending on the staining process and scanner device. Such variations affect the image analysis results. This paper presents methods to diminish the influence of color variation produced in the staining process using a calibrator slide consisting of peptide-coated microbeads. The calibrator slide is stained along with tissue sample slides, and the 3,3'-diaminobenzidine (DAB) color intensities of the microbeads are used for calibrating the color variation of the sample slides. An off-the-shelf image analysis tool is employed for the automated assessment, in which cells are classified by the thresholds for the membrane staining. We have adopted two methods for calibrating the color variation based on the DAB color intensities obtained from the calibrator slide: (1) thresholds for classifying the DAB membranous intensity are adjusted, and (2) the color intensity of WSI is corrected. In the experiment, the calibrator slides and tissue of breast cancer slides were stained together on different days and used to test our protocol. With the proposed protocol, the discordance in the HER2 evaluation was reduced to one slide out of 120 slides.

Indexed as

Breast NeoplasmsColoring AgentsCalibrationFemaleHumansImage Processing, Computer-AssistedImmunohistochemistryColoring Agentsbreast cancercolor standardizationHER2immunohistochemistry (IHC)stain intensity calibrationwhole slide image (WSI)

Identifiers

PMID38156737
PMCPMC11090401

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.