Evidence map›Paper›PMID 38155316›Full record

ArticleAnnals of biomedical engineering2024

Aqueous Humor Circulation in the Era of Minimally Invasive Surgery for Glaucoma.

Minas T Coroneo, Gabriel Graterol-Nisi, Eric Maver, R Mark Gillies

Open access · bronzeAbstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Minas T CoroneoOphthalmic Surgeons, 2 St Pauls St, Randwick, NSW, 2031, Australia. coroneom@gmail.com.ORCID http://orcid.org/0000-0002-3061-2011
Gabriel Graterol-NisiMedical Device Research Australia Pty Ltd, Sydney, Australia.
Eric MaverOphthalmic Surgeons, 2 St Pauls St, Randwick, NSW, 2031, Australia.
R Mark GilliesMedical Device Research Australia Pty Ltd, Sydney, Australia.
Prince of Wales Hospital · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Glaucoma surgery with implantation of aqueous humor draining microstents may compromise long-term corneal health by disrupting aqueous humor circulation. The effect of stent numbers on this circulation was interrogated to determine the number of stents associated with minimal circulation disruption. An in vitro anterior eye model perfusion system was constructed with multiple exit ports. A 3-D model of the anterior eye was imported into ABAQUS CFD, analyzes were carried out for unsteady laminar flow and solved using Navier-Stokes equations. DT Vision Foundry was used to analyze velocity contour plot images. The field variable results output for the CFD model were fluid wall shear, fluid pressure and fluid velocity. In vitro, "aqueous" fluid flow is high through a single stent and "aqueous" stagnation is greatest in the quadrants 180° away. Increasing stent port numbers, results in an exponential decrease in the stagnant flow locations. High wall shear stress was seen in the single stent model and is markedly reduced after a second and subsequent stents are introduced. We identify two factors potentially contributing to corneal compromise post glaucoma drainage surgery: aqueous humor stagnation, remote to the stent site and higher exit flows imparting increased stent exit shear stress (particularly with a single stent). With 4 stents, there is minimal disruption of anterior chamber circulation (mimicking physiological conditions). Furthermore we propose that aqueous humor circulation disruption via the usual single-exit port approach disrupts aqueous humor circulation with long-term consequences for corneal health.

Indexed as

Aqueous HumorGlaucomaHumansIntraocular PressureMinimally Invasive Surgical ProceduresPerfusionAqueous circulationAqueous humorCorneal endotheliumGlaucomaIntraocular pressure (IOP)Microstent

Identifiers

PMID38155316
OpenAlexW4390311825

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.