Evidence map›Paper›PMID 38154070›Full record

ArticleMedical physics2024

Microcalcification detectability in breast CT images using CNN observers.

Su Hyun Lyu, Craig K Abbey, Andrew M Hernandez, John M Boone

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Hybrid simulation of breast CT for assessing microcalcification detectability.Journal of medical imaging (Bellingham, Wash.) · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Su Hyun LyuDepartment of Biomedical Engineering, University of California Davis, Davis, California, USA.
Craig K AbbeyDepartment of Psychological and Brain Sciences, UC Santa Barbara, Santa Barbara, California, USA.
Andrew M HernandezDepartment of Radiology, University of California Davis, Sacramento, California, USA.
John M BooneDepartment of Biomedical Engineering, University of California Davis, Davis, California, USA.
University of California, Davis · USUniversity of California, Santa Barbara · US

Funding

Breast CT: Final Steps to TranslationR01CA181081 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI BOONE, JOHN M · 2015 to 2019
$2.9M
Modeling observer performance in low-dose CT assessmentsR01EB025829 · NIBIB · UNIVERSITY OF CALIFORNIA SANTA BARBARA · PI ABBEY, CRAIG KENDALL · 2018 to 2021
$1.7M
NCI NIH HHS R01 CA181081NIBIB NIH HHS R01 EB025829NIH HHS AWD101462-qNIH HHS R01 CA181081NIH HHS R01 EB025829
6 · The paper itself

Abstract

backgroundBreast computed tomography (CT) is an emerging breast imaging modality, and ongoing developments aim to improve breast CT's ability to detect microcalcifications. To understand the effects of different parameters on microcalcification detectability, a virtual clinical trial study was conducted using hybrid images and convolutional neural network (CNN)-based model observers. Mathematically generated microcalcifications were embedded into breast CT data sets acquired at our institution, and parameters related to calcification size, calcification contrast, cluster diameter, cluster density, and image display method (i.e., single slices, slice averaging, and maximum-intensity projections) were evaluated for their influence on microcalcification detectability. PURPOSE: To investigate the individual effects and the interplay of parameters affecting microcalcification detectability in breast CT.

methodsSpherical microcalcifications of varying diameters (0.04, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, 0.40 mm) and native intensities were computer simulated to portray the partial volume effects of the imaging system. Calcifications were mathematically embedded into 109 patient breast CT volume data sets as individual calcifications or as clusters of calcifications. Six numbers of calcifications (1, 3, 5, 7, 10, 15) distributed within six cluster diameters (1, 3, 5, 6, 8, 10 mm) were simulated to study the effect of cluster density. To study the role of image display method, 2D regions of interest (ROIs) and 3D volumes of interest (VOIs) were generated using single slice extraction, slice averaging, and maximum-intensity projection (MIP). 2D and 3D CNNs were trained on the ROIs and VOIs, and receiver operating characteristic (ROC) curve analysis was used to evaluate detection performance. The area under the ROC curve (AUC) was used as the primary performance metric.

resultsDetection performance decreased with increasing section thickness, and peak detection performance occurred using the native section thickness (0.2 mm) and MIP display. The MIP display method, despite using a single slice, yielded comparable performance to the native section thickness, which employed 50 slices. Reduction in slices did not sacrifice detection accuracy and provided significant computational advantages over multi-slice image volumes. Larger cluster diameters resulted in reduced overall detectability, while smaller cluster diameters led to increased detectability. Additionally, we observed that the presence of more calcifications within a cluster improved the overall detectability, while fewer calcifications decreased it.

conclusionsAs breast CT is still a relatively new breast imaging modality, there is an ongoing need to identify optimal imaging protocols. This work demonstrated the utility of MIP presentation for displaying image volumes containing microcalcification clusters. It is likely that human observers may also benefit from viewing MIPs compared to individual slices. The results of this investigation begin to elucidate how model observers interact with microcalcification clusters in a 3D volume, and will be useful for future studies investigating a broader set of parameters related to breast CT.

Indexed as

Breast DiseasesCalcinosisHumansMammographyNeural Networks, ComputerTomography, X-Ray Computedbreast CTmicrocalcificationmodel observers

Identifiers

PMID38154070
PMCPMC10922367
OpenAlexW4390322754

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.