Evidence map›Paper›PMID 38153498›Full record

ArticleActa neurochirurgica. Supplement2023

Cirq Robotic Assistance for Thoracolumbar Pedicle Screw Placement: Overcoming the Disadvantages of Minimally Invasive Spine Surgery.

Nikolay Gabrovsky, Petar Ilkov, Maria Laleva

Abstract read
PubMed Publisher
In one paragraph

Article in Acta neurochirurgica. Supplement, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
13.6field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Robot-Assisted vs Fluoroscopy-Guided Minimally Invasive Transforaminal Lumbar Interbody Fusion for Lumbar Degenerative Diseases: A Comparative Study.Medical science monitor : international medical journal of experimental and clinical research · 2025
    Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Nikolay GabrovskyDepartment of Neurosurgery, University Hospital "Pirogov", Sofia, Bulgaria.
Petar IlkovDepartment of Neurosurgery, University Hospital "Pirogov", Sofia, Bulgaria.
Maria LalevaDepartment of Neurosurgery, University Hospital "Pirogov", Sofia, Bulgaria.
National Institute of Emergency Medicine "Pirogov" · BG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionVarious minimally invasive spine surgery (MISS) techniques have been developed with the goal of reducing approach-related soft-tissue trauma and its associated complications. However, there is still a debate on some of the potential drawbacks of MISS techniques, such as their longer operating times and increased intraoperative radiation. A solution to these disadvantages could be the implementation of new technologies, such as computer-assisted navigation (CAN) and surgical robotics. We compare the standard fluoroscopy MISS technique with our experience with time per screw and X-ray exposure for pedicle screw placement using the Brainlab Cirq passive robotic arm assistance coupled with the Brainlab Curve navigation system.

methodsIn the Cirq robot-assisted group (Group I), 109 screws were placed in 24 prospectively analyzed patients. In the fluoroscopy-guided group, 108 screws inserted into 20 consecutive patients were analyzed retrospectively (Group II). The duration of surgery, the time to place one screw, the X-ray exposition, and the pedicle screw accuracy for each patient were recorded and reviewed.

resultsIn total, 217 screws were analyzed. The treated levels ranged from T10 to S1. In Group I, 104 screws were grade A (95.4%) and five were grade B (4.6%). In Group II, 96 screws were grade A (88.89%); ten were grade B (9.26%); one was grade C (0.93%), and one was grade D (0.93%). While the screws placed by using the Cirq system were more accurate overall, there was no statistical significance when the two groups were compared, p = 0.3724. There was no significant difference in radiation exposure between the two groups, p = 0.5482; however the radiation exposure for the surgeon was very limited with the Cirq system. There was a significant reduction in the operation length (p = 0.0183) and the time per screw (p < 0.0001) for Group I.

conclusionsThe CAN systems and emerging robotic platforms have the potential to diminish the main disadvantages of MISS techniques-longer operation times and X-ray exposure, at least for the surgical team.

Indexed as

Pedicle ScrewsRoboticsHumansMinimally Invasive Surgical ProceduresRetrospective StudiesSpineIntraoperative navigationMinimally invasive screw fixationPedicle screwRobot-assisted surgeryRobotic spinal surgery

Identifiers

PMID38153498
OpenAlexW4390348212

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.