Evidence map›Paper›PMID 38152701›Full record

ArticlePhysics and imaging in radiation oncology2024

Survey on fan-beam computed tomography for radiotherapy: Imaging for dose calculation and delineation.

Esther Decabooter, Guido C Hilgers, Joke De Rouck, Koen Salvo, Jacobus Van Wingerden, Hilde Bosmans, Brent van der Heyden, Sima Qamhiyeh, Chrysi Papalazarou, Robert Kaatee and 2 more

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Practical considerations for handling implants in proton therapy.Journal of applied clinical medical physics · 2025
    Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Esther DecabooterDepartment of Radiation Oncology (Maastro Clinic), GROW School for Oncology, Maastricht University Medical Centre+, Maastricht, The Netherlands.
Guido C HilgersRadiotherapiegroep, Arnhem/Deventer, The Netherlands.
Joke De RouckDepartment of Radiotherapy, AZ Sint Lucas, Ghent, Belgium.
Koen SalvoDepartment of Radiotherapy, AZ Sint-Maarten, Mechelen, Belgium.
Jacobus Van WingerdenDepartment of Medical Physics, Haaglanden Medical Centre, Leidschendam, The Netherlands.
Hilde BosmansDepartment of Medical Radiation Physics, University Hospital Leuven, Belgium.
Brent van der HeydenIBiTech-MEDISIP, Department of Electronics and Information Systems, Ghent University, Ghent, Belgium.
Sima QamhiyehUniversity Hospitals Leuven, Department of Radiation Oncology, Leuven, Belgium.
Chrysi PapalazarouDepartment of Radiotherapy, Leiden University Medical Center, Leiden, The Netherlands.
Robert KaateeRadiotherapy Institute Friesland, Leeuwarden, The Netherlands.
Geert PittomvilsDepartment of Radiation-Oncology, Ghent University Hospital, Ghent, Belgium.
Evelien BogaertDepartment of Radiation-Oncology, Ghent University Hospital, Ghent, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: To obtain an understanding of current practice, professional needs and future directions in the field of fan-beam CT in RT, a survey was conducted. This work presents the collected information regarding the use of CT imaging for dose calculation and structure delineation. Materials and methods: An online institutional survey was distributed to medical physics experts employed at Belgian and Dutch radiotherapy institutions to assess the status, challenges, and future directions of QA practices for fan-beam CT. A maximum of 143 questions covered topics such as CT scanner availability, CT scanner specifications, QA protocols, treatment simulation workflow, and radiotherapy dose calculation. Answer forms were collected between 1-Sep-2022 and 10-Oct-2022. Results: A 66 % response rate was achieved, yielding data on a total of 58 CT scanners. For MV photon therapy, all single-energy CT scans are reconstructed in Hounsfield Units for delineation or dose calculation, and a direct- or stoichiometric method was used to convert CT numbers for dose calculation. Limited use of dual-energy CT is reported for photon (N = 3) and proton dose calculations (N = 1). For brachytherapy, most institutions adopt water-based dose calculation, while approximately 26 % of the institutions take tissue heterogeneity into account. Commissioning and regular QA include eleven tasks, which are performed by two or more professions (29/31) with varying frequencies. Conclusions: Dual usage of a planning CT limits protocol optimization for both tissue characterization and delineation. DECT has been implemented only gradually. A variation of QA testing frequencies and tests are reported.

Indexed as

Computed tomographyPlanning CTProtocol optimizationQuality assuranceRadiotherapySurvey

Identifiers

PMID38152701
PMCPMC10750173

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.