Evidence map›Paper›PMID 38152237›Full record

ArticleJTCVS techniques2023

Transapical electrosurgical laceration and stabilization of mitral clips followed by transcatheter mitral valve replacement-A one-stop shop.

Joerg Kellermair, Ilinca Damian, Michael Grund, Georg Hagleitner, Florian Huber, Michael Resl, Gregor Sulzbacher, Martin Clodi, Clemens Steinwender, Andreas Zierer

Open access · goldAbstract read
In one paragraph

Article in JTCVS techniques, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
0.4field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 2 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 1 country.

Joerg KellermairDepartment of Cardiology and Internal Intensive Care Medicine, Kepler University Hospital Linz, Linz, Austria.
Ilinca DamianDepartment of Cardiothoracic and Vascular Surgery, Kepler University Hospital Linz, Linz, Austria.
Michael GrundDepartment of Cardiology and Internal Intensive Care Medicine, Kepler University Hospital Linz, Linz, Austria.
Georg HagleitnerCentral Radiology Institute, Kepler University Hospital Linz, Linz, Austria.
Florian HuberInstitute for Cardiovascular and Metabolic Research (ICMR), Faculty of Medicine, Johannes Kepler University Linz, Linz, Austria.
Michael ReslInstitute for Cardiovascular and Metabolic Research (ICMR), Faculty of Medicine, Johannes Kepler University Linz, Linz, Austria.
Gregor SulzbacherDepartment of Cardiothoracic and Vascular Surgery, Kepler University Hospital Linz, Linz, Austria.
Martin ClodiInstitute for Cardiovascular and Metabolic Research (ICMR), Faculty of Medicine, Johannes Kepler University Linz, Linz, Austria.
Clemens SteinwenderDepartment of Cardiology and Internal Intensive Care Medicine, Kepler University Hospital Linz, Linz, Austria.
Andreas ZiererInstitute for Cardiovascular and Metabolic Research (ICMR), Faculty of Medicine, Johannes Kepler University Linz, Linz, Austria.
Kepler Universitätsklinikum · ATJohannes Kepler University of Linz · ATHospital of the Brothers of St. John of God · ATWomen's General Hospital · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Electrosurgical laceration and stabilization of mitral clips (ELASTA-CLIP) is a bail-out technique to recreate a single-orifice mitral valve after transcatheter edge-to-edge repair (TEER) with subsequent transcatheter mitral valve replacement (TMVR). This technique is a novel option for patients with significant residual mitral regurgitation after TEER with high risk for conventional surgery. The original ELASTA CLIP procedure features a transseptal approach, whereas the TMVR with the Tendyne bioprosthesis has a transapical access. Hereby we tested the hypothesis that a modified transapical ELASTA CLIP technique can be safely applied transapically allowing a straightforward one-stop shop access strategy. Methods: We developed the procedural steps in a porcine passive-beating heart model and applied the modified technique with subsequent TMVR in 2 consecutive patients with severe mitral regurgitation after previous TEER. Patients were followed up to 30 days. Results: The modified transapical ELASTA CLIP procedure was successful in both patients. The mean total procedure time was 118 minutes, and the mean fluoroscopy duration 22 minutes. At 30 days' follow-up, both patients were alive without bleeding complications, reintervention, or prosthetic valve dysfunction. Conclusions: The modified transapical ELASTA CLIP procedure is technically feasible and safe at 30 days. Procedure times are lower compared with previous reports of the original transseptal approach.

Indexed as

ELASTA-CLIPelectrosurgeryTendyneTMVRtransapical

Identifiers

PMID38152237
PMCPMC10750474
OpenAlexW4386002726

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.