Evidence map›Paper›PMID 38151588›Full record

ArticleAnnals of nuclear medicine2024

Deep learning approach using SPECT-to-PET translation for attenuation correction in CT-less myocardial perfusion SPECT imaging.

Masateru Kawakubo, Michinobu Nagao, Yoko Kaimoto, Risako Nakao, Atsushi Yamamoto, Hiroshi Kawasaki, Takafumi Iwaguchi, Yuka Matsuo, Koichiro Kaneko, Akiko Sakai and 1 more

Open access · hybridAbstract read
In one paragraph

Article in Annals of nuclear medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.1field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 1 country.

Masateru KawakuboDepartment of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan.ORCID http://orcid.org/0000-0003-1867-1745
Michinobu NagaoDepartment of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan. nagao.michinobu@twmu.ac.jp.ORCID http://orcid.org/0000-0001-6049-8857
Yoko KaimotoDepartment of Radiology, Tokyo Women's Medical University, Tokyo, Japan.
Risako NakaoDepartment of Cardiology, Tokyo Women's Medical University, Tokyo, Japan.
Atsushi YamamotoDepartment of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Hiroshi KawasakiDepartment of Advanced Information Technology, Faculty of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan.
Takafumi IwaguchiDepartment of Advanced Information Technology, Faculty of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan.
Yuka MatsuoDepartment of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Koichiro KanekoDepartment of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Akiko SakaiDepartment of Cardiology, Tokyo Women's Medical University, Tokyo, Japan.
Shuji SakaiDepartment of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Tokyo Women's Medical University · JPKyushu University · JP

Funding

ACT-X JPMJAX21A7
6 · The paper itself

Abstract

objectiveDeep learning approaches have attracted attention for improving the scoring accuracy in computed tomography-less single photon emission computed tomography (SPECT). In this study, we proposed a novel deep learning approach referring to positron emission tomography (PET). The aims of this study were to analyze the agreement of representative voxel values and perfusion scores of SPECT-to-PET translation model-generated SPECT (SPECT

methodsThis retrospective study evaluated the patient-to-patient stress, resting SPECT, and PET datasets of 71 patients. The SPECT

resultsFor AHA 17-segment-wise analysis, stressed SPECT but not SPECT

conclusionsOur PET-supervised deep learning model is a new approach to correct well-known inferior wall attenuation in SPECT myocardial perfusion imaging. As standalone SPECT systems are used worldwide, the SPECT

Indexed as

Deep LearningMyocardial Perfusion ImagingHumansPositron-Emission TomographyRetrospective StudiesTomography, Emission-Computed, Single-PhotonTomography, X-Ray Computed13N ammonia PETAttenuation correctionCardiac SPECTDeep learningMyocardial perfusion imaging

Identifiers

PMID38151588
PMCPMC10884131
OpenAlexW4390348160

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.