Evidence map›Paper›PMID 38150030›Full record

ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2024

Monte-Carlo simulation for calculating phakic supplementary lenses based on a thick and thin lens model using anterior segment OCT data.

Achim Langenbucher, Alan Cayless, Kitti Kormanyos, Jascha Wendelstein, Peter Hoffmann, Nóra Szentmáry

Abstract read
In one paragraph

Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Intraocular lens power calculation formulas: a scientometric analysis.Medical hypothesis, discovery & innovation ophthalmology journal · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Achim LangenbucherDepartment of Experimental Ophthalmology, Saarland University, Kirrberger Str 100 Bldg. 2266424, Homburg/Saar, Germany. achim.langenbucher@uni-saarland.de.ORCID http://orcid.org/0000-0001-9175-6177
Alan CaylessSchool of Physical Sciences, The Open University, Milton Keynes, UK.
Kitti KormanyosDepartment of Ophthalmology, Semmelweis-University, Budapest, Hungary.
Jascha WendelsteinDepartment of Experimental Ophthalmology, Saarland University, Kirrberger Str 100 Bldg. 2266424, Homburg/Saar, Germany.
Peter HoffmannAugen- und Laserklinik Castrop-Rauxel, Castrop-Rauxel, Germany.
Nóra SzentmáryDepartment of Ophthalmology, Semmelweis-University, Budapest, Hungary.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPhakic lenses (PIOLs, the most common and only disclosed type being the implantable collamer lens, ICL) are used in patients with large or excessive ametropia in cases where laser refractive surgery is contraindicated. The purpose of this study was to present a strategy based on anterior segment OCT data for calculating the refraction correction (REF) and the change in lateral magnification (ΔM) with ICL implantation.

methodsBased on a dataset (N = 3659) containing Casia 2 measurements, we developed a vergence-based calculation scheme to derive the REF and gain or loss in ΔM on implantation of a PIOL having power PIOLP. The calculation concept is based on either a thick or thin lens model for the cornea and the PIOL. In a Monte-Carlo simulation considering, all PIOL steps listed in the US patent 5,913,898, nonlinear regression models for REF and ΔM were defined for each PIOL datapoint.

resultsThe calculation shows that simplifying the PIOL to a thin lens could cause some inaccuracies in REF (up to ½ dpt) and ΔM for PIOLs with high positive power. The full range of listed ICL powers (- 17 to 17 dpt) could correct REF in a range from - 17 to 12 dpt with a change in ΔM from 17 to - 25%. The linear regression considering anterior segment biometric data and the PIOLP was not capable of properly characterizing REF and ΔM, whereas the nonlinear model with a quadratic term for the PIOLP showed a good performance for both REF and ΔM prediction.

conclusionWhere PIOL design data are available, the calculation concept should consider the PIOL as thick lens model. For daily use, a nonlinear regression model can properly predict REF and ΔM for the entire range of PIOL steps if a vergence calculation is unavailable.

Indexed as

Lens, CrystallinePhakic Intraocular LensesHumansLens Implantation, IntraocularRefraction, OcularTomography, Optical CoherenceAnterior segment tomographyOcular magnificationPhakic lensRefraction correctionThick lens modelVergence calculation

Identifiers

PMID38150030
PMCPMC11031462

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.