Evidence map›Paper›PMID 38149093›Full record

ArticleAmerican journal of ophthalmology case reports2024

Same-quadrant Baerveldt Glaucoma Implant-250 to Baerveldt Glaucoma Implant-350 exchange.

Inae J Kim, Jessie Wang, Mary Qiu

Open access · goldAbstract readCase Reports
In one paragraph

Article in American journal of ophthalmology case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Inae J KimThe University of Chicago Department of Ophthalmology and Visual Sciences, Chicago, IL, USA.
Jessie WangThe University of Chicago Department of Ophthalmology and Visual Sciences, Chicago, IL, USA.
Mary QiuThe University of Chicago Department of Ophthalmology and Visual Sciences, Chicago, IL, USA.
University of Chicago · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: In eyes with a prior failed aqueous shunt (or "tube") requiring additional intraocular pressure (IOP) control, options include angle surgery, cyclodestruction, second tube, tube revision, or tube exchange. We present a case of a same-quadrant tube exchange of a Baerveldt-250 (BGI-250) to BGI-350. Observations: The patient is a 71-year-old African American female with severe-stage primary open angle glaucoma of both eyes, and this case focuses on the right eye. This eye had prior cataract surgery with iStent, prior BGI-250 in the anterior chamber (AC), and prior iStent removal with gonioscopy assisted transluminal trabeculotomy (GATT). The visual acuity (VA) was 20/150, and the IOP was 26 mmHg on 3 IOP-lowering medications. The prior superotemporal BGI-250 had its "wings" on top of the superior and lateral rectus muscles and its tube tip in the AC. The implant was removed in its entirety including the superficial and deep layers of its capsule. The new BGI-350 was stented with a 3-0 polypropylene ripcord, ligated with a 7-0 polyglactin suture, and implanted with its wings under the rectus muscles and the tube tip in the sulcus. For early IOP-lowering prior to ligature dissolution, 2 needle stab fenestrations and an additional 7-0 polyglactin wick was used. The capsule from the prior BGI-250 was used as a patch graft for the new BGI-350. The ligature dissolved at postoperative week (POW) 6. By POW8, the IOP was 18 mmHg on 3 IOP-lowering medications and frequent topical steroid, the AC was quiet, and the ripcord was removed. A slow steroid taper finished at postoperative month (POM) 6. By POM 12, the VA was still at baseline 20/150, and the IOP was 14 mmHg on 3 IOP-lowering medications. Conclusions & importance: Patients with a prior failed tube requiring additional IOP-lowering can undergo a same-quadrant tube exchange. BGI-350s may offer more IOP-lowering than BGI-250s, but the IOP-lowering achieved in this patient's case could be attributable to differences in postoperative management in addition to endplate size; longer follow-up is needed. A tube exchange offers the opportunity to reposition the tube tip from the AC to the sulcus and to use the prior tube's capsule as a patch graft for the new tube.

Indexed as

Aqueous shuntAutologous patch graftBaerveldt-250Baerveldt-350Capsule autograftTube exchangeTube revisionTube shunt

Identifiers

PMID38149093
PMCPMC10750127
OpenAlexW4389431074

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.