Evidence map›Paper›PMID 38148960›Full record

ArticleJournal of biomedical physics & engineering2023

Evaluation of Radiation Treatment Planning Algorithms in IMRT and VMAT: A Comparative Dosimetric Study in Lung Equivalent Heterogeneous Medium.

Atul Mishra, Ramji Pathak, Teerth Raj Verma, Anoop Kumar Srivastava, Surendra Prasad Mishra, Kailash Kumar Mittal, Sudesh Kumar Singh

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical physics & engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Atul MishraDepartment of Physics, Tilak Dhari P. G. College, Jaunpur, (U.P.) - 222002, India.
Ramji PathakDepartment of Physics, Tilak Dhari P. G. College, Jaunpur, (U.P.) - 222002, India.
Teerth Raj VermaDepartment of Radiotherapy, King George Medical University, Lucknow (U.P.) - 226003, India.
Anoop Kumar SrivastavaDepartment of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow (U.P.) 226010, India.
Surendra Prasad MishraDepartment of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow (U.P.) 226010, India.
Kailash Kumar MittalDepartment of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Saifai, Etawah (U.P.) - 206130, India.
Sudesh Kumar SinghDepartment of Physics, Tilak Dhari P. G. College, Jaunpur, (U.P.) - 222002, India.
Adesh University · INDr. Ram Manohar Lohia Institute of Medical Sciences · INTilak Dhari Post Graduate College · INKing George's Medical University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In Radiotherapy, computation of dose is important since in a small field with heterogeneity, dose is usually computed with discrepancies. Objective: The present study was aimed to evaluate the dosimetry of treatment planning algorithms in lung equivalent heterogeneous medium for Volumetric Modulated Arc Therapy (VMAT) with step and shoot Intensity-Modulated Radiation Therapy (ss-IMRT), and dynamic Intensity-Modulated Radiation Therapy (d-IMRT). Material and Methods: In this experimental study, Computerized Imaging Reference System (CIRS) phantom was used with an inhomogeneous Racemosa wood cylinder for two types of tumors, namely, Left Lung Central Tumor (LCT) and Left Lung Peripheral Tumor (LPT) in the CIRS left lung cavity. The computed tomography (CT) datasets were employed with the generation of VMAT, d-IMRT and ss-IMRT plans for the LCT and LPT irradiated with 6 MV photon beams. In this study, the accuracy and efficacy of two algorithms: Monte Carlo (MC) and the Pencil Beam (PB), from the Monaco treatment planning system (TPS), were tested by using Gafchromic EBT3 films and CIRS thorax phantom. Results: Regardless of treatment techniques, both algorithms exhibited higher divergence in LPT than LCT. In both LCT and LPT, the highest deviation was near the tumor-lung junction. However, the deviation was higher in the PB algorithm than MC algorithm, with a minimally acceptable variation of -0.8%. Conclusion: The MC algorithm shows more consistency for EBT3 measured dose in lung equivalent heterogeneous medium. However, accurate dose predictions are complicated due to electronic disequilibrium within and at the interface of inhomogeneity. These constraints may cause variations from the anticipated outcomes of the treatments.

Indexed as

AlgorithmsComputed TomographyGafchromic FilmLungMonte CarloRadiotherapy

Identifiers

PMID38148960
PMCPMC10749411
OpenAlexW4389105544

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.