ArticleJapanese journal of radiology2024
Serial assessment of computed tomography angiography for pulmonary and systemic arteries using a reduced contrast agent dose for the diagnosis of systemic artery-to-pulmonary artery shunts.
Article in Japanese journal of radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 0 citations in OpenAlex.
- Photon-counting detector computed tomography in thoracic oncology: revolutionizing tumor imaging through precision and detail.Diagnostic and interventional radiology (Ankara, Turkey) · 2026Review
- The hemodynamic and clinical characteristics of recurrent hemoptysis in bronchiectasis patients after vascular intervention procedures.Journal of thoracic disease · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo evaluate the diagnostic performance and feasibility of a modified computed tomography (CT) scan protocol, we performed a serial assessment of the computed tomography angiography for pulmonary artery (CTA-P) and systemic artery (CTA-S) (CTA-PS) using a reduced contrast agent dose to diagnose systemic artery-to-pulmonary artery shunts (SPSs). MATERIALS AND
methodsTwenty-five patients who underwent multiphase contrast-enhanced chest CT and conventional chest angiography were included. Three image sets (CTA-P, CTA-S, and CTA-PS) were evaluated by two board-certified radiologists. The visualization of the CT image findings associated with SPSs, such as filling defects and enhancement in the pulmonary arteries, was evaluated using a 5-point scale.
resultsThe diagnostic performance (sensitivity, specificity, and accuracy) of CT imaging findings associated with SPSs in CTA-P and CTA-PS were as follows: CTA-P, 57.1%, 87.5%, and 62.0%; CTA-PS, 81.0%, 100.0%, and 84.0%. CT findings associated with SPSs in CTA-P were significantly sensitive to the CTA-PS protocol. There were no significant differences between the CTA-S and CTA-PS protocols. The area under the curve (AUC) of the CT imaging findings associated with SPSs in the CTA-P and CTA-PS groups was 0.835 and 0.911, respectively (P = 0.191). The AUC of the CT imaging findings associated with SPSs in CTA-S and CTA-PS were 0.891 and 0.926, respectively (P = 0.373).
conclusionCTA-PS using a reduced contrast agent dose protocol could improve the overall diagnostic confidence of SPSs, owing to better visualization of CT imaging findings associated with SPSs compared to individual assessments of CTA-P or CTA-S. Therefore, CTA-PS can be used as an alternative preembolization evaluation modality to conventional angiography in patients with hemoptysis suspected of having SPSs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.