Evidence map›Paper›PMID 38147169›Full record

ArticleEuropean radiology2024

Quantifying cup overhang after total hip arthroplasty: standardized measurement using reformatted computed tomography and association of overhang distance with iliopsoas impingement.

Adrian A Marth, Christian Ofner, Patrick O Zingg, Reto Sutter

Open access · hybridAbstract read
In one paragraph

Article in European radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Adrian A MarthSwiss Center for Musculoskeletal Imaging, Balgrist Campus AG, Zurich, Switzerland. adrian.marth@balgristcampus.ch.ORCID http://orcid.org/0000-0002-7334-0757
Christian OfnerDepartment of Radiology, Balgrist University Hospital, Faculty of Medicine, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
Patrick O ZinggDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
Reto SutterDepartment of Radiology, Balgrist University Hospital, Faculty of Medicine, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
University of Zurich · CHUniversitätsklinik Balgrist · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesCurrently, there is no standardized measurement method for evaluating cup overhang (CO) in patients undergoing total hip arthroplasty (THA). We propose a novel, standardized method of measuring overhang distance in patients following primary total hip arthroplasty (THA) on computed tomography (CT) images after multiplanar reformation and compare it to a previously proposed measurement method on sagittal CT images. MATERIALS AND

methodsThis retrospective study included patients who underwent primary THA with an anterior approach. Patients with cup overhang (CO) and iliopsoas impingement (IPI) were identified by clinical and imaging data. Uncorrected overhang distance (OD

resultsOut of 220 patients with THA, 23 patients (10.4%) with CO and 16 patients (7.3%) with IPI were identified. CO was significantly associated to IPI (p < 0.001). The inter- and intrareader agreement was almost perfect for OD

conclusionWe implemented a novel measurement method for CT images reformatted at the plane of the cup face to assess overhang distance in patients with CO following THA. CLINICAL RELEVANCE STATEMENT: While further validation is necessary, the proposed method is characterized by its high reproducibility and might be used to predict the occurrence of iliopsoas impingement in patients with cup overhang following total hip arthroplasty. KEY POINTS: • A novel, standardized method of measuring cup overhang distance in patients following primary total hip arthroplasty on CT images is proposed. • Cup overhang was associated to iliopsoas impingement. The proposed method was reproducible and showed excellent prediction of iliopsoas impingement in patients with cup overhang. • This method can be implemented in clinical practice when assessing CT images of patients with cup overhang for iliopsoas impingement.

Indexed as

Arthroplasty, Replacement, HipTomography, X-Ray ComputedAcetabulumAdultAgedAged, 80 and overFemaleHip ProsthesisHumansMaleMiddle AgedPsoas MusclesRetrospective StudiesArthroplasty (replacement, hip)ImpingementPain (postoperative)Tomography (x-ray computed)

Identifiers

PMID38147169
PMCPMC11213778
OpenAlexW4390234000

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.