Evidence map›Paper›PMID 38139923›Full record

ArticlePolymers2023

Investigation of Novel Solid Dielectric Material for Transformer Windings.

Aysel Ersoy, Fatih Atalar, Alper Aydoğan

Abstract read
In one paragraph

Article in Polymers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Aysel ErsoyDepartment of Electrical and Electronic Engineering, Istanbul University-Cerrahpasa, Bağlariçi St. No. 7, Avcılar, 34320 Istanbul, Turkey.ORCID 0000-0003-1164-7187
Fatih AtalarDepartment of Electrical and Electronic Engineering, Istanbul University-Cerrahpasa, Bağlariçi St. No. 7, Avcılar, 34320 Istanbul, Turkey.ORCID 0000-0002-0179-3108
Alper AydoğanComputing & Information Services Office, Muğla Sıtkı Koçman University, Kötekli Campus, 48000 Muğla, Turkey.ORCID 0000-0001-8936-9792

Funding

Istanbul University-Cerrahpaşa FBA-2023-37284
6 · The paper itself

Abstract

Improvement techniques aimed at enhancing the dielectric strength and minimizing the dielectric loss of insulation materials have piqued the interest of many researchers. It is worth noting that the electrical breakdown traits of insulation material are determined by their electrochemical and mechanical performance. Possible good mechanical, electrical, and chemical properties of new materials are considered during the generation process. Thermoplastic polyurethane (TPU) is often used as a high-voltage insulator due to its favorable mechanical properties, high insulation resistance, lightweight qualities, recovery, large actuation strain, and cost-effectiveness. The elastomer structure of thermoplastic polyurethane (TPU) enables its application in a broad range of high-voltage (HV) insulation systems. This study aims to evaluate the feasibility of using TPU on transformer windings as a solid insulator instead of pressboards. The investigation conducted through experiments sheds light on the potential of TPU in expanding the range of insulating materials for HV transformers. Transformers play a crucial role in HV systems, hence the selection of suitable materials like cellulose and polyurethane is of utmost importance. This study involved the preparation of an experimental setup in the laboratory. Breakdown tests were conducted by generating a non-uniform electric field using a needle-plane electrode configuration in a test chamber filled with mineral oil. Various voltages ranging from 14.4 kV to 25.2 kV were applied to induce electric field stress with a step rise of 3.6 kV. The partial discharges and peak numbers were measured based on the predetermined threshold values. The study investigated and compared the behaviors of two solid insulating materials under differing non-electric field stress conditions. Harmonic component analysis was utilized to observe the differences between the two materials. Notably, at 21.6 kV and 25.2 kV, polyurethane demonstrated superior performance compared to pressboard with regards to the threshold value of leakage current.

Indexed as

breakdownharmonicspolyurethanepressboardtransformers mineral oil

Identifiers

PMID38139923
PMCPMC10747763

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.