Evidence map›Paper›PMID 38139649›Full record

ArticleSensors (Basel, Switzerland)2023

Optimization Method to Predict Optimal Noise Reduction Parameters for the Non-Local Means Algorithm Based on the Scintillator Thickness in Radiography.

Bo Kyung Cha, Kyeong-Hee Lee, Youngjin Lee, Kyuseok Kim

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Bo Kyung ChaPrecision Medical Device Research Center, Korea Electrotechnology Research Institute (KERI), 111 Hanggaul-ro, Sangnok-gu, Ansan-si 15588, Republic of Korea.
Kyeong-Hee LeePrecision Medical Device Research Center, Korea Electrotechnology Research Institute (KERI), 111 Hanggaul-ro, Sangnok-gu, Ansan-si 15588, Republic of Korea.
Youngjin LeeDepartment of Radiological Science, Gachon University, 191 Hambangmoe-ro, Yeonsu-gu, Incheon 21936, Republic of Korea.
Kyuseok KimDepartment of Biomedical Engineering, Eulji University, 553 Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Republic of Korea.

Funding

Korean government (the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, the Ministry of Food and Drug Safety) Project Number:1711194312, RS-2020-KD000014Ministry of Science and ICT No. 23A01114
6 · The paper itself

Abstract

The resulting image obtained from an X-ray imaging system depends significantly on the characteristics of the detector. In particular, when an X-ray image is acquired by thinning the detector, a relatively large amount of noise inevitably occurs. In addition, when a thick detector is used to reduce noise in X-ray images, blurring increases and the ability to distinguish target areas deteriorates. In this study, we aimed to derive the optimal X-ray image quality by deriving the optimal noise reduction parameters based on the non-local means (NLM) algorithm. The detectors used were of two thicknesses (96 and 140 μm), and images were acquired based on the IEC 62220-1-1:2015 RQA-5 protocol. The optimal parameters were derived by calculating the edge preservation index and signal-to-noise ratio according to the sigma value of the NLM algorithm. As a result, a sigma value of the optimized NLM algorithm (0.01) was derived, and this algorithm was applied to a relatively thin X-ray detector system to obtain appropriate noise level and spatial resolution data. The no-reference-based blind/referenceless image spatial quality evaluator value, which analyzes the overall image quality, was best when using the proposed method. In conclusion, we propose an optimized NLM algorithm based on a new method that can overcome the noise amplification problem in thin X-ray detector systems and is expected to be applied in various photon imaging fields in the future.

Indexed as

image quality assessmentimage restorationnoise reductionnon-local means (NLM) methodparameter optimizationscintillator thickness

Identifiers

PMID38139649
PMCPMC10747373

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.