Evidence map›Paper›PMID 38139620›Full record

ArticleSensors (Basel, Switzerland)2023

Non-Invasive Assessment of Abdominal/Diaphragmatic and Thoracic/Intercostal Spontaneous Breathing Contributions.

Ella F S Guy, Jaimey A Clifton, Jennifer L Knopp, Lui R Holder-Pearson, J Geoffrey Chase

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. A Novel Approach for Treating Benign Pleural Effusions-First in Human Application of a Diaphragmatic Pleuro-Peritoneal Valve.European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2026
    Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Ella F S GuyCentre for Bioengineering, Mechanical Engineering, University of Canterbury, Christchurch 8041, New Zealand.ORCID 0000-0002-2704-9096
Jaimey A CliftonCentre for Bioengineering, Mechanical Engineering, University of Canterbury, Christchurch 8041, New Zealand.
Jennifer L KnoppCentre for Bioengineering, Mechanical Engineering, University of Canterbury, Christchurch 8041, New Zealand.
Lui R Holder-PearsonElectrical and Computer Engineering, University of Canterbury, Christchurch 8041, New Zealand.
J Geoffrey ChaseCentre for Bioengineering, Mechanical Engineering, University of Canterbury, Christchurch 8041, New Zealand.ORCID 0000-0001-9989-4849
University of Canterbury · NZ

Funding

MSCA-RISE-2019 #872488 DCPMUniversity of Canterbury 94322484
6 · The paper itself

Abstract

(1) Background: Technically, a simple, inexpensive, and non-invasive method of ascertaining volume changes in thoracic and abdominal cavities are required to expedite the development and validation of pulmonary mechanics models. Clinically, this measure enables the real-time monitoring of muscular recruitment patterns and breathing effort. Thus, it has the potential, for example, to help differentiate between respiratory disease and dysfunctional breathing, which otherwise can present with similar symptoms such as breath rate. Current automatic methods of measuring chest expansion are invasive, intrusive, and/or difficult to conduct in conjunction with pulmonary function testing (spontaneous breathing pressure and flow measurements). (2) Methods: A tape measure and rotary encoder band system developed by the authors was used to directly measure changes in thoracic and abdominal circumferences without the calibration required for analogous strain-gauge-based or image processing solutions. (3) Results: Using scaling factors from the literature allowed for the conversion of thoracic and abdominal motion to lung volume, combining motion measurements correlated to flow-based measured tidal volume (normalised by subject weight) with R

Indexed as

Respiratory MechanicsThoracic WallAbdomenAdultDiaphragmHumansLungabdominalcircumferencemonitoringmuscular recruitmentrespiratory mechanicsrotary encoderthoracic

Identifiers

PMID38139620
PMCPMC10747041
OpenAlexW4389623642

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.