Evidence map›Paper›PMID 38139488›Full record

ArticleSensors (Basel, Switzerland)2023

Research on Transformer Omnidirectional Partial Discharge Ultrasound Sensing Method Combining F-P Cavity and FBG.

Guochao Qian, Weigen Chen, Kejie Wu, Hong Liu, Jianxin Wang, Zhixian Zhang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Guochao QianState Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China.
Weigen ChenState Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China.
Kejie WuState Grid Tianfu New Area Electric Power Supply Company, Chengdu 610213, China.
Hong LiuState Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China.
Jianxin WangState Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China.
Zhixian ZhangSchool of Electrical and Electronic Engineering, Chongqing University of Technology, Chongqing 400054, China.

Funding

science & technology project of State Grid Corporation of China 5108 202299263A-1-0-ZB
6 · The paper itself

Abstract

To achieve omnidirectional sensitive detection of partial discharge (PD) in transformers and to avoid missing PD signals, a fiber optic omnidirectional sensing method for PD in transformers combined with the fiber Bragg grating (FBG) and Fabry-Perot (F-P) cavity is proposed. The fiber optic omnidirectional sensor for PD as a triangular prism was developed. The hollow structure of the probe was used to insert a single-mode fiber to form an F-P cavity. In addition, the three sides of the probe were used to form a diaphragm-type FBG sensing structure. The ultrasound sensitization diaphragm was designed based on the frequency characteristics of PD in the transformer and the vibration model of the diaphragm in the liquid environment. The fiber optic sensing system for PD was built and the performance test was conducted. The results show that the resonant frequency of the FBG acoustic diaphragm is around 20 kHz and that of the F-P cavity acoustic diaphragm is 94 kHz. The sensitivity of the developed fiber optic sensor is higher than that of the piezoelectric transducer (PZT). The lower limit of PD detection is 68.72 pC for the FBG sensing part and 47.97 pC for the F-P cavity sensing part. The directional testing of the sensor and its testing within a transformer simulation model indicate that the proposed sensor achieves higher detection sensitivity of PD in all directions. The omnidirectional partial discharge ultrasound sensing method proposed in this paper is expected to reduce the missed detection rate of PD.

Indexed as

Fabry-Perot cavityfiber Bragg gratingfiber optic sensoromnidirectionalpartial dischargeultrasound sensing

Identifiers

PMID38139488
PMCPMC10747692

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.