ArticleSensors (Basel, Switzerland)2023
Research on Transformer Omnidirectional Partial Discharge Ultrasound Sensing Method Combining F-P Cavity and FBG.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Localization for Dual Partial Discharge Sources in Transformer Oil Using Pressure-Balanced Fiber-Optic Ultrasonic Sensor Array.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
To achieve omnidirectional sensitive detection of partial discharge (PD) in transformers and to avoid missing PD signals, a fiber optic omnidirectional sensing method for PD in transformers combined with the fiber Bragg grating (FBG) and Fabry-Perot (F-P) cavity is proposed. The fiber optic omnidirectional sensor for PD as a triangular prism was developed. The hollow structure of the probe was used to insert a single-mode fiber to form an F-P cavity. In addition, the three sides of the probe were used to form a diaphragm-type FBG sensing structure. The ultrasound sensitization diaphragm was designed based on the frequency characteristics of PD in the transformer and the vibration model of the diaphragm in the liquid environment. The fiber optic sensing system for PD was built and the performance test was conducted. The results show that the resonant frequency of the FBG acoustic diaphragm is around 20 kHz and that of the F-P cavity acoustic diaphragm is 94 kHz. The sensitivity of the developed fiber optic sensor is higher than that of the piezoelectric transducer (PZT). The lower limit of PD detection is 68.72 pC for the FBG sensing part and 47.97 pC for the F-P cavity sensing part. The directional testing of the sensor and its testing within a transformer simulation model indicate that the proposed sensor achieves higher detection sensitivity of PD in all directions. The omnidirectional partial discharge ultrasound sensing method proposed in this paper is expected to reduce the missed detection rate of PD.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.