Active-Passive Joint Acoustic Emission Monitoring Test Considering the Heterogeneity of Concrete.

Zhehan Chen, Tianjiao Miao, Tao Liu, Xuandong Chen, Aiping Yu

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.7field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Zhehan ChenCollege of Civil and Architectural Engineering, Guilin University of Technology, Guilin 541004, China.
Tianjiao MiaoCollege of Civil and Architectural Engineering, Guilin University of Technology, Guilin 541004, China.
Tao LiuCollege of Civil and Architectural Engineering, Guilin University of Technology, Guilin 541004, China.
Xuandong ChenCollege of Civil and Architectural Engineering, Guilin University of Technology, Guilin 541004, China.ORCID 0000-0002-8504-6870
Aiping YuCollege of Civil and Architectural Engineering, Guilin University of Technology, Guilin 541004, China.
Guilin University of Technology · CN

Funding

Guangxi Natural Science Foundation 2022GXNSFAA035553Innovation Project of Guangxi Graduate Education YCSW2023367National Natural Science Foundation of China 51968014
6 · The paper itself

Abstract

The heterogeneity of concrete is a major challenge for acoustic emission monitoring. A method of active-passive joint acoustic emission monitoring considering the heterogeneity of concrete is presented herein, and the time-frequency-space multi-parameter response characteristics of active and passive acoustic emission signals were studied in relation to the damage evolution of concrete. This method provides an idea of evaluating the damage state of concrete more actively and quantitatively than traditional methods. The results show that the microscopic damage model of concrete based on the acoustic emission penetrating wave velocity and amplitude is in agreement with the damage process of concrete. The standard deviation of the wave velocity up to 1000 m/s and the change rate of the amplitude up to -0.66 can be adopted as two signs that the load of concrete reached 70% of the ultimate load. The time-of-arrival localization based on variable velocity was used to correct the acoustic emission localization results, and the localization accuracy was increased by 44.74%. The damage process of concrete undergoes diverse changes; that is, the distribution of damage changes from heterogeneous to homogeneous and then back to heterogeneous. Hence, it is necessary for researchers to consider the heterogeneity of concrete when using acoustic emission monitoring. The active-passive joint acoustic emission monitoring is an effective method.

Indexed as

active-passive joint acoustic emission monitoringamplitudeconcretetime-of-arrival localizationwave velocity

Identifiers

PMID38138836
PMCPMC10744926
OpenAlexW4389912665

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.