ArticleMaterials (Basel, Switzerland)2023
Frequency Response Evaluation as Diagnostic and Optimization Tool for Pulsed Unipolar Plasma Electrolytic Oxidation Process and Resultant Coatings on Zirconium.
Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- High-Frequency Plasma Electrolytic Oxidation of an Al-Si Alloy: Influence of AlMaterials (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 3 countries.
Funding
Abstract
This study aims to bridge various diagnostic tools for the development of smart plasma electrolytic oxidation (PEO) technologies. PEO treatments of commercially pure Zr were carried out using the pulsed unipolar polarisation (PUP) regime with frequency sweep in an alkaline phosphate-silicate electrolyte. Methods of in situ impedance spectroscopy and electrical transient analysis were used for the process diagnostics under the video imaging of the PEO. Two cutoff frequencies, 170-190 Hz and 620-650 Hz, were identified for the PEO-assisted charge transfer process. An equivalent circuit for the metal-oxide-electrolyte system under PUP PEO conditions was developed; from the capacitance values, two geometrical dielectric barriers were evaluated: a thinner 0.5-1 µm inner layer of the coating and a thicker 4-6 µm outer layer. These estimates were in agreement with the coating cross-sectional morphology. Based on comparing the results obtained using different techniques, the frequencies at which the uniform coatings with the best protective properties were formed were identified. For the selected electrolyte system and polarisation regime, these frequencies ranged from 2 to 5 kHz where the overall circuit reactance was minimal; therefore, the power factor was as close to one as possible. This opens the possibilities for the optimization of the pulsed PEO process and online control of unobservable surface characteristics, e.g., the thickness of the coating layers, thus contributing towards the development of smart PEO technologies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials