Evidence map›Paper›PMID 38138366›Full record

ArticleMicromachines2023

Low-Cost Optical pH Sensor with a Polyaniline (PANI)-Sensitive Layer Based on Commercial Off-the-Shelf (COTS) Components.

Serguei Stoukatch, Marc Debliquy, Francois Dupont, Jean-Michel Redouté

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Serguei StoukatchMicrosys Laboratory, Department of Electrical Engineering and Computer Science (Montefiore Institute), University of Liège, 4000 Liège, Belgium.ORCID 0000-0002-5060-4086
Marc DebliquyService de Science des Matériaux, Faculté Polytechnique, Université de Mons, 7000 Mons, Belgium.
Francois DupontMicrosys Laboratory, Department of Electrical Engineering and Computer Science (Montefiore Institute), University of Liège, 4000 Liège, Belgium.ORCID 0000-0002-2939-4694
Jean-Michel RedoutéMicrosys Laboratory, Department of Electrical Engineering and Computer Science (Montefiore Institute), University of Liège, 4000 Liège, Belgium.ORCID 0000-0001-9612-4312

Funding

European Regional Development Fund (ERDF) and Wallonia (Belgium). No. 675781-642409Wallonia (Belgium) No. 1510608
6 · The paper itself

Abstract

In this paper, we presented a novel, compact, conceptually simple, and fully functional low-cost prototype of a pH sensor with a PANI thin film as a sensing layer. The PANI deposition process is truly low-cost; it performs from the liquid phase, does not required any specialized equipment, and comprises few processing steps. The resulting PANI layer has excellent stability, resistance to solvents, and bio- and chemical compatibility. The pH sensor's sensing part includes only a few components such as a red-light-emitting diode (LED) as a light source, and a corresponding photodiode (PD) as a detector. Unlike other PANI-based sensors, it requires no sophisticated and expensive techniques and components such lasers to excite the PANI or spectrometry to identify the PANI color change induced by pH variation. The pH sensor is sensitive in the broad pH range of 3 to 9, which is useful for numerous practical applications. The sensor requires a tiny volume of the test specimen, as little as 55 µL. We developed a fully integrated packaging solution for the pH sensor that comprises a limited number of components. The pH sensor comprises exclusively commercial off-the-shelf (COTS) components and standard printed circuit boards. The pH sensor is assembled using standard surface mounting technology (SMT).

Indexed as

colorimetric characterizationCOTS componentsoptical pH sensoroptical sensorpolyaniline

Identifiers

PMID38138366
PMCPMC10745723

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.