Evidence map›Paper›PMID 38138317›Full record

ArticleMicromachines2023

Numerical Analysis of Stress Force on Vessel Walls in Atherosclerotic Plaque Removal through Coronary Rotational Atherectomy.

Zhaoju Zhu, Liujing Chen, Weijie Yu, Chuhang Gao, Bingwei He

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Zhaoju ZhuCollege of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350108, China.
Liujing ChenCollege of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350108, China.
Weijie YuCollege of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350108, China.
Chuhang GaoCollege of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350108, China.
Bingwei HeCollege of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350108, China.
Fuzhou University · CN

Funding

National Natural Science Foundation of China 52205455Natural and Science Foundation of Fujian Province 2021J01560
6 · The paper itself

Abstract

Coronary rotational atherectomy is an effective technique for treating cardiovascular disease by removing calcified tissue using small rotary grinding tools. However, it is difficult to analyze the stress force on vessel walls using experiments directly. Using computational fluid dynamics is a better way to study the stress force characteristics of the burr grinding procedure from a fluid dynamics perspective. For this purpose, physical and simulation models of atherosclerotic plaque removal were constructed in this study. The simulation results show that smaller ratios between the burr and arterial diameter (B/A = 0.5) result in a more stable flow field domain. Additionally, the pressure and stress force generated by the 4.5 mm diameter grinding tool reach 92.77 kPa and 10.36 kPa, surpassing those of the 2.5 mm and 3.5 mm grinding tools. The study has demonstrated the use of computational fluid dynamics to investigate wall shear stress characteristics in medical procedures, providing valuable guidance for optimizing the procedure and minimizing complications.

Indexed as

coronary rotational atherectomygrinding toolnumerical simulationstress force

Identifiers

PMID38138317
PMCPMC10745720
OpenAlexW4388974419

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.