Evidence map›Paper›PMID 38137650›Full record

ArticleJournal of clinical medicine2023

Enhancing Precision and Efficiency in Knee Arthroplasty: A Comparative Analysis of Computer-Assisted Measurements with a Novel Software Tool versus Manual Measurements for Lower Leg Geometry.

Ulrike Wittig, Amir Koutp, Patrick Reinbacher, Konstanze Hütter, Andreas Leithner, Patrick Sadoghi

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ulrike WittigDepartment of Orthopaedics and Trauma, Medical University of Graz, 8036 Graz, Austria.ORCID 0000-0002-9415-1728
Amir KoutpDepartment of Orthopaedics and Trauma, Medical University of Graz, 8036 Graz, Austria.ORCID 0000-0001-5992-4708
Patrick ReinbacherDepartment of Orthopaedics and Trauma, Medical University of Graz, 8036 Graz, Austria.ORCID 0000-0003-0786-8956
Konstanze HütterDepartment of Orthopaedics and Trauma, Medical University of Graz, 8036 Graz, Austria.
Andreas LeithnerDepartment of Orthopaedics and Trauma, Medical University of Graz, 8036 Graz, Austria.ORCID 0000-0002-2598-2325
Patrick SadoghiDepartment of Orthopaedics and Trauma, Medical University of Graz, 8036 Graz, Austria.ORCID 0000-0003-1767-555X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: The aim of this prospective study was to evaluate measurement software in comparison with manual measurements using inter-observer and intra-observer variability on radiographs in the preoperative planning of total knee arthroplasty. (2) Methods: Two independent observers retrospectively measured the mechanical lateral proximal femoral angle (mLPFA), the mechanical lateral distal femoral angle (mLDFA), the joint line convergence angle (JLCA), the mechanical medial proximal tibial angle (mMPTA), the mechanical lateral distal tibial angle (mLDTA), the hip-knee angle or mechanical tibial-femoral axis angle (HKA), and the anatomical-mechanical angle (AMA) on 55 long-leg anteroposterior radiographs manually twice, followed by measurements using dedicated software. Variability between manual and computer-aided planning was assessed, and all measurements were performed a second time after 14 days in order to assess intra-observer variability. (3) Results: Concerning intra-observer variability, no statistically significant difference was observed regarding the software-based measurements. However, significant differences were noted concerning intra-observer variability when measuring the mLDFA and AMA manually. Testing for statistical significance regarding variability between manual and software-based measurements showed that the values varied strongly between manual and computer-aided measurements. Statistically significant differences were detected for mLPFA, mLDFA, mMPTA, and mLPTA on day 1, and mLPFA, mMPTA, and mLPTA on day 15, respectively. (4) Conclusions: Preoperative planning of leg axis angles and alignment using planning software showed less inter- and intra-observer variability in contrast to manual measurements, and results differed with respect to manual planning. We believe that the planning software is more reliable and faster, and we would recommend its use in clinical settings.

Indexed as

leg axisleg axis alignmentleg axis anglesplanning software

Identifiers

PMID38137650
PMCPMC10743611

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials