Evidence map›Paper›PMID 38136647›Full record

ArticleBiomolecules2023

Selection of Aptamers for Use as Molecular Probes in AFM Detection of Proteins.

Maria O Ershova, Amir Taldaev, Petr V Konarev, Georgy S Peters, Anastasia A Valueva, Irina A Ivanova, Sergey V Kraevsky, Andrey F Kozlov, Vadim S Ziborov, Yuri D Ivanov and 2 more

Open access · goldAbstract read
In one paragraph

Article in Biomolecules, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 1 country.

Maria O ErshovaInstitute of Biomedical Chemistry, Pogodinskaya Str. 10/8, 119121 Moscow, Russia.
Amir TaldaevInstitute of Biomedical Chemistry, Pogodinskaya Str. 10/8, 119121 Moscow, Russia.
Petr V KonarevA.V. Shubnikov Institute of Crystallography of Federal Scientific Research Centre "Crystallography and Photonics" of Russian Academy of Sciences, Leninsky Ave. 59, 119333 Moscow, Russia.ORCID 0000-0002-5606-1596
Georgy S PetersNational Research Centre "Kurchatov Institute", Akademika Kurchatova Square 1, 123182 Moscow, Russia.
Anastasia A ValuevaInstitute of Biomedical Chemistry, Pogodinskaya Str. 10/8, 119121 Moscow, Russia.
Irina A IvanovaInstitute of Biomedical Chemistry, Pogodinskaya Str. 10/8, 119121 Moscow, Russia.
Sergey V KraevskyInstitute of Biomedical Chemistry, Pogodinskaya Str. 10/8, 119121 Moscow, Russia.
Andrey F KozlovInstitute of Biomedical Chemistry, Pogodinskaya Str. 10/8, 119121 Moscow, Russia.
Vadim S ZiborovInstitute of Biomedical Chemistry, Pogodinskaya Str. 10/8, 119121 Moscow, Russia.
Yuri D IvanovInstitute of Biomedical Chemistry, Pogodinskaya Str. 10/8, 119121 Moscow, Russia.ORCID 0000-0001-5041-1914
Alexander I ArchakovInstitute of Biomedical Chemistry, Pogodinskaya Str. 10/8, 119121 Moscow, Russia.
Tatyana O PleshakovaInstitute of Biomedical Chemistry, Pogodinskaya Str. 10/8, 119121 Moscow, Russia.ORCID 0000-0003-3217-9095
Institute of Biomedical Chemistry · RUKurchatov Institute · RURussian Academy of Sciences · RU

Funding

The Ministry of Education and Science of the Russian Federation 075-15-2021-933, unique project ID: RF00121X0004
6 · The paper itself

Abstract

Currently, there is great interest in the development of highly sensitive bioanalytical systems for diagnosing diseases at an early stage, when pathological biomarkers are present in biological fluids at low concentrations and there are no clinical manifestations. A promising direction is the use of molecular detectors-highly sensitive devices that detect signals from single biomacromolecules. A typical detector in this class is the atomic force microscope (AFM). The high sensitivity of an AFM-based bioanalysis system is determined by the size of the sensing element of an atomic force microscope-the cantilever-the radius of the curvature of which is comparable to that of a biomolecule. Biospecific molecular probe-target interactions are used to ensure detection system specificity. Antibodies, aptamers, synthetic antibodies, and peptides can be used as molecular probes. This study has demonstrated the possibility of using aptamers as molecular probes for AFM-based detection of the ovarian cancer biomarker CA125. Antigen detection in a nanomolar solution was carried out using AFM chips with immobilized aptamers, commercially available or synthesized based on sequences from open sources. Both aptamer types can be used for antigen detection, but the availability of sequence information enables additional modeling of the aptamer structure with allowance for modifications necessary for immobilization of the aptamer on an AFM chip surface. Information on the structure and oligomeric composition of aptamers in the solution was acquired by combining small-angle X-ray scattering and molecular modeling. Modeling enabled pre-selection, before the experimental stage, of aptamers for use as surface-immobilized molecular probes.

Indexed as

Aptamers, NucleotideMicroscopy, Atomic ForceModels, MolecularMolecular ProbesAptamers, NucleotideMolecular ProbesAFMaptamersbio specific interactionCA125protein detectionSAXS

Identifiers

PMID38136647
PMCPMC10742151
OpenAlexW4389624330

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.