Evidence map›Paper›PMID 38136030›Full record

ArticleBioengineering (Basel, Switzerland)2023

Improved Hypertension Risk Assessment with Photoplethysmographic Recordings Combining Deep Learning and Calibration.

Jesús Cano, Vicente Bertomeu-González, Lorenzo Fácila, Fernando Hornero, Raúl Alcaraz, José J Rieta

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jesús CanoBioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain.ORCID 0000-0003-3660-9777
Vicente Bertomeu-GonzálezCardiovascular Research Group, Clinical Medicine Department, Miguel Hernández University, 03202 Alicante, Spain.ORCID 0000-0001-5309-0562
Lorenzo FácilaCardiology Department, General University Hospital Consortium of Valencia, 46014 Valencia, Spain.ORCID 0000-0003-1402-4364
Fernando HorneroCardiovascular Surgery Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain.ORCID 0000-0002-7560-2781
Raúl AlcarazResearch Group in Electronic, Biomedical and Telecommunication Engineering, University of Castilla-La Mancha, 16071 Cuenca, Spain.ORCID 0000-0002-0942-3638
José J RietaBioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain.ORCID 0000-0002-3364-6380

Funding

European Regional Development Fund (EU) 10.13039/501100011033Generalitat Valenciana AICO/2021/286Government of Spain PID2021-00X128525-IV0Government of Spain PID2021-123804OB-I00Government of Spain TED2021-130935B-I00Regional Government of Castile-La Mancha SBPLY/17/180501/000411Regional Government of Castile-La Mancha SB-PLY/21/180501/000186
6 · The paper itself

Abstract

Hypertension, a primary risk factor for various cardiovascular diseases, is a global health concern. Early identification and effective management of hypertensive individuals are vital for reducing associated health risks. This study explores the potential of deep learning (DL) techniques, specifically GoogLeNet, ResNet-18, and ResNet-50, for discriminating between normotensive (NTS) and hypertensive (HTS) individuals using photoplethysmographic (PPG) recordings. The research assesses the impact of calibration at different time intervals between measurements, considering intervals less than 1 h, 1-6 h, 6-24 h, and over 24 h. Results indicate that calibration is most effective when measurements are closely spaced, with an accuracy exceeding 90% in all the DL strategies tested. For calibration intervals below 1 h, ResNet-18 achieved the highest accuracy (93.32%), sensitivity (84.09%), specificity (97.30%), and F1-score (88.36%). As the time interval between calibration and test measurements increased, classification performance gradually declined. For intervals exceeding 6 h, accuracy dropped below 81% but with all models maintaining accuracy above 71% even for intervals above 24 h. This study provides valuable insights into the feasibility of using DL for hypertension risk assessment, particularly through PPG recordings. It demonstrates that closely spaced calibration measurements can lead to highly accurate classification, emphasizing the potential for real-time applications. These findings may pave the way for advanced, non-invasive, and continuous blood pressure monitoring methods that are both efficient and reliable.

Indexed as

blood pressurecalibrationdeep learninghypertensionphotoplethysmography

Identifiers

PMID38136030
PMCPMC10741001

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.