Evidence map›Paper›PMID 38136023›Full record

ArticleBioengineering (Basel, Switzerland)2023

Non-Invasive Electroanatomical Mapping: A State-Space Approach for Myocardial Current Density Estimation.

Erik Engelhardt, Eric Elzenheimer, Johannes Hoffmann, Christy Meledeth, Norbert Frey, Gerhard Schmidt

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Erik EngelhardtDepartment of Electrical Information Engineering, Faculty of Engineering, Kiel University, Kaiserstr. 2, 24143 Kiel, Germany.ORCID 0000-0002-7012-7707
Eric ElzenheimerDepartment of Electrical Information Engineering, Faculty of Engineering, Kiel University, Kaiserstr. 2, 24143 Kiel, Germany.ORCID 0000-0002-4841-4646
Johannes HoffmannDepartment of Electrical Information Engineering, Faculty of Engineering, Kiel University, Kaiserstr. 2, 24143 Kiel, Germany.ORCID 0000-0001-8170-8147
Christy MeledethInternal Medicine 1-Cardiology and Internal Intensive Care Medicine, Med Campus III, Kepler University Hospital, Krankenhausstraße 9, 4021 Linz, Austria.
Norbert FreyDepartment of Internal Medicine III (Cardiology, Angiology and Pneumonology), University Medical Center Heidelberg, Im Neuenheimer Feld 410, 69120 Heidelberg, Germany.
Gerhard SchmidtDepartment of Electrical Information Engineering, Faculty of Engineering, Kiel University, Kaiserstr. 2, 24143 Kiel, Germany.ORCID 0000-0002-6128-4831

Funding

Deutsche Forschungsgemeinschaft CRC1261
6 · The paper itself

Abstract

Electroanatomical mapping is a method for creating a model of the electrophysiology of the human heart. Medical professionals routinely locate and ablate the site of origin of cardiac arrhythmias with invasive catheterization. Non-invasive localization takes the form of electrocardiographic (ECG) or magnetocardiographic (MCG) imaging, where the goal is to reconstruct the electrical activity of the human heart. Non-invasive alternatives to catheter electroanatomical mapping would reduce patients' risks and open new venues for treatment planning and prevention. This work introduces a new system state-based method for estimating the electrical activity of the human heart from MCG measurements. Our model enables arbitrary propagation paths and velocities. A Kalman filter optimally estimates the current densities under the given measurements and model parameters. In an outer optimization loop, these model parameters are then optimized via gradient descent. This paper aims to establish the foundation for future research by providing a detailed mathematical explanation of the algorithm. We demonstrate the feasibility of our method through a simplified one-layer simulation. Our results show that the algorithm can learn the propagation paths from the magnetic measurements. A threshold-based segmentation into healthy and pathological tissue yields a DICE score of 0.84, a recall of 0.77, and a precision of 0.93.

Indexed as

biomagnetismgradient descentKalman filtermagnetocardiography (MCG)noninvasive cardiac diagnosticsoptimization

Identifiers

PMID38136023
PMCPMC10741003

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.