ArticleBioengineering (Basel, Switzerland)2023
The Effect of Cerclage Banding Distally to a Clamshell Fracture Pattern in Total Hip Arthroplasty-A Biomechanical Study.
Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Management of Clamshell Fractures in Total Hip Arthroplasty: A Rarely Recognized Periprosthetic Injury Pattern.Journal of clinical medicine · 2025Review
- Cementless long-stem fixation in periprosthetic clamshell fracture: a biomechanical investigation.Frontiers in bioengineering and biotechnology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesAs currently there is no existing biomechanical work on the topic of interest, the aim of the current study was to investigate the effect of cerclage banding distally to an intraoperatively occurring proximal periprosthetic femoral clamshell fracture versus a non-fractured femur after total hip arthroplasty.
methodsA diaphyseal anchoring stem was implanted in twenty paired human cadaveric femora, assigned to a treatment and a control group. In the treatment group, each specimen was fitted with a cerclage band placed 3 mm distally to a clamshell fracture, created with an extent of 40% of the anchoring length of the stem. The resulting fragment was not treated further. The contralateral specimens were left with the stems without further fracture creation or treatment. All constructs were tested under progressively increasing cyclic axial loading until failure. Relative bone-implant movements were monitored by motion tracking.
resultsNumber of cycles and the corresponding load at stem loosening, defined as 1 mm displacement of the stem along the shaft axis, were 31,417 ± 8870 and 3641.7 ± 887 N in the control group, and 26,944 ± 11,706 and 3194.4 ± 1170.6 N in the treatment group, respectively, with no significant differences between them,
conclusionFrom a biomechanical perspective, cerclage banding distally to an intraoperative clamshell fracture with an extent of 40% of the anchoring length of the stem demonstrated comparable resistance against hip stem loosening versus a non-fractured femur. It may therefore represent a valid treatment option to restore the full axial stability of a diaphyseal anchoring stem. In addition, it may be considered to keep the medial wall fragment unfixed, thus saving operative time and minimizing associated risks.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.