Evidence map›Paper›PMID 38135955›Full record

ArticleBioengineering (Basel, Switzerland)2023

Validation of the Finite Element Model versus Biomechanical Assessments of Dental Implants and Total Knee Replacements.

Kwan-Su Kang, Kwang-Min Park, Jin-Woo Ahn, Min-Young Jo, Yu-Rim Oh, Jin-Ho Youn, Jeong-Woo Lee, Dong-Young Je, Tae-Gon Jung

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Kwan-Su KangMedical Device Development Center, Osong Medical Innovation Foundation, Cheongju-si 28160, Republic of Korea.ORCID 0000-0001-5536-8804
Kwang-Min ParkMedical Device Development Center, Osong Medical Innovation Foundation, Cheongju-si 28160, Republic of Korea.
Jin-Woo AhnMedical Device Development Center, Osong Medical Innovation Foundation, Cheongju-si 28160, Republic of Korea.
Min-Young JoDepartment of Biomedical Engineering, College of Biomedical Science & Engineering, Inje University, Gimhae-si 50834, Republic of Korea.
Yu-Rim OhDepartment of Biomedical Engineering, College of Biomedical Science & Engineering, Inje University, Gimhae-si 50834, Republic of Korea.
Jin-Ho YounDepartment of Biomedical Engineering, College of Biomedical Science & Engineering, Inje University, Gimhae-si 50834, Republic of Korea.ORCID 0009-0004-9833-7513
Jeong-Woo LeeDepartment of Biomedical Engineering, College of Biomedical Science & Engineering, Inje University, Gimhae-si 50834, Republic of Korea.
Dong-Young JeDepartment of Biomedical Engineering, College of Biomedical Science & Engineering, Inje University, Gimhae-si 50834, Republic of Korea.
Tae-Gon JungMedical Device Development Center, Osong Medical Innovation Foundation, Cheongju-si 28160, Republic of Korea.ORCID 0000-0002-4793-9125

Funding

Ministry of Food and Drug Safety RS-2023-00215638
6 · The paper itself

Abstract

Computer modeling and simulation (CM&S) technology is widely used in the medical device industry due to its advantages such as reducing testing time and costs. However, the developer's parameter settings during the modeling and simulation process can have a significant impact on the results. This study developed a test model for the rotational shear strength of dental implants and the constraint force of total knee replacements based on CM&S technology and proposes ideal parameters to ensure reliability. For dental implants, the load area and sliding contact conditions were considered, and for total knee replacements, the friction coefficient, medial-lateral displacement, valgus-varus rotation, and elastic modulus were considered. By comparing the simulation results and mechanical tests, boundary conditions with an error rate of less than 1.5% were selected. When a jig (gripper and collector) was applied with the same boundary conditions, an error rate of 48~22% occurred; otherwise, it was confirmed that the error rate was within 10~0.2%. The FE model was verified with an error of 2.49 to 3% compared to the mechanical test. The friction coefficient variable had the greatest influence on the results, accounting for 10 to 13%, and it was confirmed that valgus-varus rotation had a greater influence on the results than medial-lateral displacement. Relatively, the elastic modulus of the insert had the least effect on the results. These research results are expected to make CM&S techniques useful as a medical device digital development tool (M3DT) in the development of total knee replacements and dental implants.

Indexed as

dental implantfinite element methodtotal knee replacement

Identifiers

PMID38135955
PMCPMC10740907

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked