Evidence map›Paper›PMID 38135882›Full record

ArticleJournal of orthopaedic surgery and research2023

Investigating the reliability and validity of subacromial space measurements using ultrasound and MRI.

Stephen M Boulanger, Alexandra Mahna, Talia Alenabi, Anthony A Gatti, Oriana Culig, Loriann M Hynes, Jaclyn N Chopp-Hurley

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
  6. ShapeMed-Knee: A Dataset and Neural Shape Model Benchmark for Modeling 3D Femurs.medRxiv : the preprint server for health sciences · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Stephen M BoulangerSchool of Kinesiology and Health Science, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada.
Alexandra MahnaSchool of Kinesiology and Health Science, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada.
Talia AlenabiDepartment of Kinesiology, University of Waterloo, Waterloo, ON, Canada.
Anthony A GattiDepartment of Radiology, Stanford University, Stanford, CA, USA.
Oriana CuligSchool of Kinesiology and Health Science, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada.
Loriann M HynesSchool of Kinesiology and Health Science, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada.
Jaclyn N Chopp-HurleySchool of Kinesiology and Health Science, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada. jnhurley@yorku.ca.

Funding

Natural Sciences and Engineering Research Council of Canada Discovery GrantYork University Junior Faculty Funds and Minor Research Grant
6 · The paper itself

Abstract

backgroundWhile ultrasound (US) measures of the subacromial space (SAS) have demonstrated excellent reliability, measurements are typically captured by experts with extensive ultrasound experience. Further, the agreement between US measured SAS width and other imaging modalities has not been explored. This research evaluated the agreement between SAS measures captured by novice and expert raters and between US and magnetic resonance imaging (MRI). This study also evaluated the effect of US transducer tilt on measured SAS.

methodsNine men and nine women participated in this study. US images were captured by a novice and expert with the participant in both seated and supine positions. An inclinometer was fixed to the US probe to measure transducer tilt. SAS width was measured in real time from freeze framed images. MRI images were captured, and the humerus and acromion manually segmented. The SAS width was measured using a custom algorithm.

resultsIntraclass correlation coefficients (ICCs) between novice and expert raters were 0.74 and 0.63 for seated and supine positions, respectively. Intra-rater agreement was high for both novice (ICC = 0.83-0.84) and expert (ICC ≥ 0.94) raters. Agreement between US and MRI was poor (ICC = 0.21-0.49) but linearly related.

conclusionsModerate agreement between novice and expert raters was demonstrated, while the agreement between US and MRI was poor. High intra-rater reliability within each rater suggests that US measures of the SAS may be completed by a novice with introductory training.

Indexed as

AlgorithmsMagnetic Resonance ImagingFemaleHumansMaleReproducibility of ResultsSitting PositionUltrasonographyMagnetic resonance imagingReliabilityShoulderUltrasound

Identifiers

PMID38135882
PMCPMC10740303

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.