Evidence map›Paper›PMID 38135738›Full record

ArticleObesity surgery2024

Evaluation of a Magnetic Compression Anastomosis for Jejunoileal Partial Diversion in Rhesus Macaques.

Lauren L Evans, William G Lee, Mohammad Karimzada, Veeshal H Patel, Vamsi K Aribindi, Dillon Kwiat, James L Graham, David E Cummings, Peter J Havel, Michael R Harrison

Open access · hybridAbstract read
In one paragraph

Article in Obesity surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Comparative study of cylindricalWorld journal of gastrointestinal surgery · 2025
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Lauren L EvansDepartment of Surgery, University of California San Francisco, San Francisco, USA.
William G LeeDepartment of Surgery, University of California San Francisco, San Francisco, USA.
Mohammad KarimzadaDepartment of Surgery, University of California San Francisco, San Francisco, USA.
Veeshal H PatelDepartment of Surgery, University of California San Francisco, San Francisco, USA.
Vamsi K AribindiDepartment of Surgery, University of California San Francisco, San Francisco, USA.
Dillon KwiatDepartment of Surgery, University of California San Francisco, San Francisco, USA.
James L GrahamDepartment of Molecular Biosciences, School of Veterinary Medicine and Department of Nutrition, University of California Davis, Davis, USA.
David E CummingsDivision of Metabolism, Endocrinology and Nutrition, University of Washington and VA Puget Sound Health Care System, Seattle, USA.
Peter J HavelDepartment of Molecular Biosciences, School of Veterinary Medicine and Department of Nutrition, University of California Davis, Davis, USA.
Michael R HarrisonDepartment of Surgery, University of California San Francisco, San Francisco, USA. Michael.Harrison@ucsf.edu.ORCID 0000-0003-0866-7005
University of California, San Francisco · USUniversity of California, Davis · USUniversity of Washington · US

Funding

National Institute on Aging (NIA) ColonyP51OD011107 · OD · UNIVERSITY OF CALIFORNIA AT DAVIS · PI Simon J. Atkinson · 2012 to 2026
$191.5M
NIH HHS P51 OD011107
6 · The paper itself

Abstract

purposeMetabolic surgery remains underutilized for treating type 2 diabetes, as less invasive alternative interventions with improved risk profiles are needed. We conducted a pilot study to evaluate the feasibility of a novel magnetic compression device to create a patent limited caliber side-to-side jejunoileal partial diversion in a nonhuman primate model. MATERIALS AND

methodsUsing an established nonhuman primate model of diet-induced insulin resistance, a magnetic compression device was used to create a side-to-side jejunoileal anastomosis. Primary outcomes evaluated feasibility (e.g., device mating and anastomosis patency) and safety (e.g., device-related complications). Secondary outcomes evaluated the device's ability to produce metabolic changes associated with jejunoileal partial diversion (e.g., homeostatic model assessment of insulin resistance [HOMA-IR] and body weight).

resultsDevice mating, spontaneous detachment, and excretion occurred in all animals (n = 5). There were no device-related adverse events. Upon completion of the study, ex vivo anastomoses were widely patent with healthy mucosa and no evidence of stricture. At 6 weeks post-device placement, HOMA-IR improved to below baseline values (p < 0.05). Total weight also decreased in a linear fashion (R

conclusionThe use of this novel magnetic compression device to create a limited caliber side-to-side jejunoileal anastomosis is safe and likely feasible in a nonhuman primate model. The observed glucoregulatory and metabolic effects of a partial jejunoileal bypass with this device warrant further investigation to validate the long-term glucometabolic impact of this approach.

Indexed as

Diabetes Mellitus, Type 2Insulin ResistanceObesity, MorbidAnastomosis, SurgicalAnimalsMacaca mulattaMagnetic PhenomenaPilot ProjectsInsulin resistanceMagnamosisMagnetic compression deviceMetabolic surgerySmall-bowel anastomosisStaple-free anastomosis

Identifiers

PMID38135738
PMCPMC10810932
OpenAlexW4390144359

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.