Evidence map›Paper›PMID 38133653›Full record

SynthesisEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2024

Robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials.

Reda Alrajeb, Mohammed Zarti, Zakaria Shuia, Osama Alzobi, Ghalib Ahmed, Aissam Elmhiregh

Abstract readSystematic ReviewMeta-AnalysisComparative Study
In one paragraph

Synthesis in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 87 papers, 9 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
87citing papers in PubMed, 9 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

87 citing papers in PubMed, 9 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Pooled it
  7. Pooled it
  8. Pooled it
  9. Pooled it
  10. Improved surgical accuracy in total knee arthroplasty using the ROSA® knee system: A randomised-controlled unblinded trial.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
    Trial
  11. Trial
  12. Review
  13. Article
  14. Review
  15. [Research progress of cementless prosthesis in total knee arthroplasty].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Review
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article

27 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Reda AlrajebAlmowasafat Hospital, Tripoli, Libya.
Mohammed ZartiAlmowasafat Hospital, Tripoli, Libya.
Zakaria ShuiaAlmowasafat Hospital, Tripoli, Libya.
Osama AlzobiDepartment of Orthopedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar. osama94zoubi@yahoo.com.ORCID http://orcid.org/0000-0002-0327-7967
Ghalib AhmedDepartment of Orthopedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar.
Aissam ElmhireghAlmowasafat Hospital, Tripoli, Libya.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesRobotic knee arthroplasty procedures have emerged as a new trend, garnering attention from orthopedic surgeons globally. It has been hypothesized that the use of robotics enhances the accuracy of prosthesis positioning and alignment restoration. The objective of this study was to provide a high-level, evidence-based comparison between robotic total knee replacements and conventional methods, focusing on radiological and functional outcomes.

methodsWe searched five databases from their inception until June 1, 2022, specifically targeting randomized controlled trials (RCTs) that compared the outcomes of robotic and conventional total knee replacements. We were interested in outcomes such as knee range of motion, clinical and function knee society scores, the Western Ontario and McMaster University score (WOMAC), the Hospital of Special Surgery score, complications, and radiological alignment. This review was carried out in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyzes guidelines. We assessed the risk of bias using the revised Cochrane risk-of-bias tool for randomized trials (RoB 2).

resultsOur search returned seven RCTs suitable for our analysis, which included a total of 1942 knees; 974 of these knees were implanted using robotic arms while the remaining 968 utilized jig-based knee systems. Our findings indicated that robotic knees had significantly better post-operative anatomical (OR - 0.82; 95% CI, - 1.027 to - 0.58, p value < 0.00001) and mechanical restoration (OR - 0.95; 95% CI, - 1.49 to - 0.41, p value < 0.0006). While knee range of motion (OR - 2.23; 95% CI - 4.89-0.43, p value 0.1) and femoral prosthesis position (OR - 0.98; 95% CI, - 2.03-0.08, p value 0.07) also favored robotic knees, these differences did not reach statistical significance. Both clinical and functional outcomes, as well as the rate of complications, were found to be statistically similar between the groups undergoing robotic and traditional knee replacement surgeries.

conclusionThis meta-analysis indicates that robotic total knee replacements offer superior post-operative anatomical and mechanical alignment compared to conventional total knee replacements. Despite this, clinical and functional outcomes, as well as complication rates, were similar between the two. These findings should be considered in light of potential confounding factors. More randomized controlled trials with the latest robotic systems are needed to confirm any superior functional and clinical outcomes from robotic-assisted surgeries. LEVEL OF EVIDENCE: I.

Indexed as

Arthroplasty, Replacement, KneeRandomized Controlled Trials as TopicRange of Motion, ArticularRobotic Surgical ProceduresHumansKnee JointPostoperative ComplicationsTreatment OutcomeConventional knee arthroplastyJig-based arthroplastyRobotic arthroplastyTotal knee arthroplasty

Identifiers

PMID38133653
PMCPMC10980635

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.