Evidence map›Paper›PMID 38133495›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2024

Skin-Interfaced Bifluidic Paper-Based Device for Quantitative Sweat Analysis.

Muhan Deng, Xiaofeng Li, Kui Song, Hanlin Yang, Wenkui Wei, Xiaojun Duan, Xiaoping Ouyang, Huanyu Cheng, Xiufeng Wang

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Skin-Interfaced Bifluidic Paper-Based Device for Quantitative Sweat Analysis.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Muhan DengSchool of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan, 411105, China.
Xiaofeng LiSchool of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan, 411105, China.
Kui SongDepartment of Engineering Science and Mechanics, Xiangtan University, Xiangtan, Hunan, 411105, China.
Hanlin YangSchool of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan, 411105, China.
Wenkui WeiSchool of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan, 411105, China.
Xiaojun DuanHunan Provincial Children's Hospital, Changsha, Hunan, 410000, China.
Xiaoping OuyangSchool of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan, 411105, China.
Huanyu ChengDepartment of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA.ORCID 0000-0001-6075-4208
Xiufeng WangSchool of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan, 411105, China.ORCID 0000-0002-9557-049X

Funding

Smart skin grafts for quantitative assessment and treatment of diabetic woundsR21EB030140 · NIBIB · PENNSYLVANIA STATE UNIVERSITY, THE · PI CHENG, HUANYU · 2021 to 2021
$620k
NIBIB NIH HHS R21 EB030140NIH HHS R21EB030140
6 · The paper itself

Abstract

The erratic, intermittent, and unpredictable nature of sweat production, resulting from physiological or psychological fluctuations, poses intricacies to consistently and accurately sample and evaluate sweat biomarkers. Skin-interfaced microfluidic devices that rely on colorimetric mechanisms for semi-quantitative detection are particularly susceptible to these inaccuracies due to variations in sweat secretion rate or instantaneous volume. This work introduces a skin-interfaced colorimetric bifluidic sweat device with two synchronous channels to quantify sweat rate and biomarkers in real-time, even during uncertain sweat activities. In the proposed bifluidic-distance metric approach, with one channel to measure sweat rate and quantify collected sweat volume, the other channel can provide an accurate analysis of the biomarkers based on the collected sweat volume. The closed channel design also reduces evaporation and resists contamination from the external environment. The feasibility of the device is highlighted in a proof-of-the-concept demonstration to analyze sweat chloride for evaluating hydration status and sweat glucose for assessing glucose levels. The low-cost yet highly accurate device provides opportunities for clinical sweat analysis and disease screening in remote and low-resource settings. The developed device platform can be facilely adapted for the other biomarkers when corresponding colorimetric reagents are exploited.

Indexed as

SkinSweatBiomarkersGlucoseLab-On-A-Chip DevicesBiomarkersGlucosedistance-based metric approachpaper-based microfluidic devicesweat chloridesweat glucosesweat rate and volume

Identifiers

PMID38133495
PMCPMC10933605

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.