Evidence map›Paper›PMID 38132897›Full record

ArticleMembranes2023

Study on UF PES Membranes Spray-Coated with Polymerizable Bicontinuous Microemulsion Materials for Low-Fouling Behavior.

Sneha De, Jonathan Heer, Suwetha Sankar, Fabian Geiger, Ephraim Gukelberger, Francesco Galiano, Raffaella Mancuso, Bartolo Gabriele, Alberto Figoli, Jan Hoinkis

Abstract read
In one paragraph

Article in Membranes, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Sneha DeCenter of Applied Research (CAR), Karlsruhe University of Applied Sciences (HKA), Moltkestrasse 30, 76133 Karlsruhe, Germany.
Jonathan HeerCenter of Applied Research (CAR), Karlsruhe University of Applied Sciences (HKA), Moltkestrasse 30, 76133 Karlsruhe, Germany.
Suwetha SankarCenter of Applied Research (CAR), Karlsruhe University of Applied Sciences (HKA), Moltkestrasse 30, 76133 Karlsruhe, Germany.
Fabian GeigerCenter of Applied Research (CAR), Karlsruhe University of Applied Sciences (HKA), Moltkestrasse 30, 76133 Karlsruhe, Germany.
Ephraim GukelbergerCenter of Applied Research (CAR), Karlsruhe University of Applied Sciences (HKA), Moltkestrasse 30, 76133 Karlsruhe, Germany.
Francesco GalianoInstitute on Membrane Technology (ITM-CNR), Via P. Bucci 17c, 87036 Rende, CS, Italy.ORCID 0000-0003-0536-552X
Raffaella MancusoLaboratory of Industrial and Synthetic Organic Chemistry (LISOC), Department of Chemistry and Chemical Technology (CTC), University of Calabria, Via P. Bucci 12/C, 87036 Rende, CS, Italy.ORCID 0000-0001-7514-6096
Bartolo GabrieleLaboratory of Industrial and Synthetic Organic Chemistry (LISOC), Department of Chemistry and Chemical Technology (CTC), University of Calabria, Via P. Bucci 12/C, 87036 Rende, CS, Italy.ORCID 0000-0003-4582-1489
Alberto FigoliInstitute on Membrane Technology (ITM-CNR), Via P. Bucci 17c, 87036 Rende, CS, Italy.ORCID 0000-0002-3347-0506
Jan HoinkisCenter of Applied Research (CAR), Karlsruhe University of Applied Sciences (HKA), Moltkestrasse 30, 76133 Karlsruhe, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The low-fouling propensity of commercially available polyethersulfone (PES) membranes was studied after modification of the membrane surface via coating with polymerizable bicontinuous microemulsion (PBM) materials. The PBM coating was polymerized within 1 min using ultraviolet (UV) light exposure. It was detected on the PES membrane surface via attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy. The PBM coating led to an average 10% increase in the hydrophilicity of the PES membrane surface and an increase in total organic content (TOC) removal by more than 15%. Flux-step tests were conducted with model foulant comprising 100 mg L

Indexed as

critical fluxfouling propensitylow-fouling layermembrane foulingPBM-coated membranesspray coating

Identifiers

PMID38132897
PMCPMC10744386

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.