Evidence map›Paper›PMID 38132497›Full record

ArticleBiomimetics (Basel, Switzerland)2023

Ground Contact Force and Moment Estimation for Human-Exoskeleton Systems Using Dynamic Decoupled Coordinate System and Minimum Energy Hypothesis.

Hongwu Li, Haotian Ju, Junchen Liu, Ziqi Wang, Qinghua Zhang, Xianglong Li, Yi Huang, Tianjiao Zheng, Jie Zhao, Yanhe Zhu

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hongwu LiState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
Haotian JuState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
Junchen LiuState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
Ziqi WangState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
Qinghua ZhangState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
Xianglong LiState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0001-6208-2580
Yi HuangState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
Tianjiao ZhengState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
Jie ZhaoState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
Yanhe ZhuState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.

Funding

Tianjiao Zheng No. 52105016
6 · The paper itself

Abstract

Estimating the contact forces and moments (CFMs) between exoskeletons' feet and the ground is a prerequisite for calculating exoskeletons' joint moments. However, comfortable, portable, and high-precision force sensors for CFM detection are difficult to design and manufacture. In addition, there are many unknown CFM components (six force components and six moment components in the double-support phase). These reasons make it challenging to estimate CFMs precisely. In this paper, we propose a novel method for estimating these CFMs based on a proposed dynamic decoupled coordinate system (DDCS) and the minimum energy hypothesis. By decomposing these CFMs into a DDCS, the number of unknowns can be significantly reduced from twelve to two. Meanwhile, the minimum energy hypothesis provides a relatively reliable target for optimizing the remaining two unknown variables. We verify the accuracy of this method using a public data set about human walking. The validation shows that the proposed method is capable of estimating CFMs. This study provides a practical way to estimate the CFMs under the soles, which contributes to reducing the research and development costs of exoskeletons by avoiding the need for expensive plantar sensors. The sensor-free approach also reduces the dependence on high-precision, portable, and comfortable CFM detection sensors, which are usually difficult to design.

Indexed as

dynamic decoupled coordinate systemexoskeletonground contact force and moment estimationminimum energy hypothesis

Identifiers

PMID38132497
PMCPMC10741984

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.