ArticleInternational journal of dentistry2023

Comparative Evaluation of the Effect of Implant Crown Materials on Implant Components and Bone Stress Distribution: A 3D Finite Element Analysis.

Kimia Nokar, Faezeh Atri, Saied Nokar

Abstract read
In one paragraph

Article in International journal of dentistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Kimia NokarSchool of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
Faezeh AtriDepartment of Prosthodontics, School of Dentistry, Craniomaxillofacial Research Center, Tehran University of Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0000-0002-4334-6154
Saied NokarDepartment of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0000-0003-2278-4697

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Choosing implant crown materials for restoration remains challenging in clinical practice. This study assesses the impact of all-ceramic restoration instead of porcelain-fused-to-metal (PFM) restoration on the stress distribution within implant components and the surrounding bone. Methods: Four 3D models of a mandibular second premolar were meticulously prepared. The study groups comprised zirconia, lithium disilicate, and zirconia lithium silicate monolithic ceramic crowns cemented onto a zirconia hybrid abutment. A PFM crown cemented onto a cementable abutment was chosen as the control group. A total vertical load of 583 N was applied to the occlusal contact areas. Stress distribution within the crown and implant components was analyzed using von Mises stress analysis. Principal stress analyses were employed to assess stress distribution in the peripheral bone. Results: The PFM model exhibited the highest von Mises stress values for both the implant (428.7 MPa) and crown (79.7 MPa) compared to the other models. The all-ceramic models displayed the highest maximum von Mises stress within the abutment, approximately 335 MPa, compared to the PFM model. von Mises stresses of the abutment and implant in the all-ceramic models were 69% higher and 20% lower, respectively, than those in the PFM model. Screw stresses were relatively consistent across all groups. Principal stresses in spongy bone and minimum principal stress in cortical bone were consistent across all models. Conclusions: All-ceramic restoration with a hybrid abutment, as opposed to traditional PFM restoration with a cementable abutment, does not adversely affect the implant and abutment screw and reduces crown stresses. Stresses within hybrid abutments were notably higher than those within cementable abutments. Spongy bone stresses remained unaffected by the type of crown or abutment.

Identifiers

PMID38130700
PMCPMC10735729

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.