Evidence map›Paper›PMID 38130631›Full record

ArticleJournal of clinical orthopaedics and trauma2023

3D-printed patient specific surgical guides: Balancing accuracy with practicality.

Yiu Hin Kwan, Dean Owyang, Sean Wei Loong Ho, Michael Gui Jie Yam

Open access · greenAbstract read
In one paragraph

Article in Journal of clinical orthopaedics and trauma, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Yiu Hin KwanDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, 308433, Singapore.
Dean OwyangDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, 308433, Singapore.
Sean Wei Loong HoDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, 308433, Singapore.
Michael Gui Jie YamDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, 308433, Singapore.
Tan Tock Seng Hospital · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Three-dimensional (3D) printing technology has been used in orthopaedic surgery in recent years to manufacture customized surgical cutting jigs. However, there is scarcity of literature and information regarding the optimal parameters of an ideal jig. Our study aims to determine the optimum parameters to design surgical jigs that can produce accurate cuts, and remain practical for use, to serve as a guide for jig creation in future. Methods and materials: A biomechanical lab study was designed to investigate whether the thickness of a jig and the height of its cutting slot can significantly affect cutting accuracy. Surgical jigs were 3D printed in medical grade, and an oscillating sawblade was used to mimic intraoperative surgical cuts through the cutting slots onto wooden blocks, which were then analysed to determine the accuracy of cuts. Results: Statistical analysis was performed on a total of 72 cuts. The cutting accuracy increased when the thickness of the jig increased, at all slot heights. The cutting accuracy also increased as the slot height decreased, at all jig thicknesses. Overall, the parameters for jig construction that yielded the most accurate cuts were a jig thickness of 15 mm, in combination with a slot height of 100 % of the width of the sawblade. Additionally, at a jig thickness of 15 mm, there was no statistically significant difference in cutting accuracy when increasing the slot height to 120 %. Conclusion: This study is the first to propose tangible parameters that can be applied to surgical jig construction to obtain reproducible accurate cuts. Provided that a jig of 15 mm thickness can be accommodated by the size of the wound, the ideal surgical jig with a superior balance of accuracy and useability is 15 mm thick, with a cutting slot height of 120 % of the sawblade thickness.

Indexed as

BiomechanicsPatient-specificPrintingSurgical jigThree-dimensional

Identifiers

PMID38130631
PMCPMC10731221
OpenAlexW4389068437

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.