ArticleJournal of cardiology cases2023
Flow characteristics of in-situ internal thoracic artery graft with competitive flow.
Article in Journal of cardiology cases, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 3 citations in OpenAlex.
- UV-cure hydrogels for cardiac regeneration: a comprehensive review.Stem cell research & therapy · 2025Review
- Fast Fourier transform analysis of intraoperative transit-time flow measurement during coronary artery bypass grafting.Journal of cardiothoracic surgery · 2024Review
- Cardiac tissue engineering: an emerging approach to the treatment of heart failure.Frontiers in bioengineering and biotechnology · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We report flow characteristics of an in-situ internal thoracic artery (LITA) graft with angiographically competitive flow to the left anterior descending artery (LAD), based upon intraoperative transit-time flow measurement (TTFM) during coronary artery bypass grafting with aortic valve replacement (AVR) and during re-AVR seven years later. Although intraoperative TTFM of the graft showed lower mean flow and higher pulsatility index, suggesting inadequate anastomosis, fast Fourier transform (FFT) analysis of TTFM waveforms presented gradual waning of the amplitude, as shown in patent grafts. FFT analysis of the TTFM waveforms is helpful to judge the patency of LITA to LAD, even with competitive flow. Learning objective: The internal thoracic artery (LITA) graft to left anterior descending artery (LAD) with angiographically competitive flow shows gradual waning of the amplitude on fast Fourier transform (FFT) analysis of the transit-time flow measurement (TTFM) waveforms, although lower mean graft flow, higher pulsatility index, and higher systolic reversal flow may suggest inadequate anastomosis. FFT analysis of the TTFM waveforms is useful to judge the patency of LITA to LAD, even with competitive flow.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.